{"product_id":"schneider-electric-advanced-power-base-tesys-u-3p-12a-690v-lub120","title":"Advanced power base, TeSys U, 3P, 12A\/690V - LUB120","description":"\u003cdiv class=\"section-product-attributes\"\u003e \u003cdiv\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eRange of product:\u003c\/th\u003e\n\u003ctd\u003e TeSys U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRange:\u003c\/th\u003e\n\u003ctd\u003e TeSys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct name:\u003c\/th\u003e\n\u003ctd\u003e TeSys U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDevice short name:\u003c\/th\u003e\n\u003ctd\u003e LUB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct or component type:\u003c\/th\u003e\n\u003ctd\u003e Non reversing power base\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDevice application:\u003c\/th\u003e\n\u003ctd\u003e Motor controlMotor protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePoles description:\u003c\/th\u003e\n\u003ctd\u003e 3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSuitability for isolation:\u003c\/th\u003e\n\u003ctd\u003e Yes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e[Ue] rated operational voltage:\u003c\/th\u003e\n\u003ctd\u003e 690 V AC for power circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNetwork frequency:\u003c\/th\u003e\n\u003ctd\u003e 40...60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e[Ith] conventional free air thermal current:\u003c\/th\u003e\n\u003ctd\u003e 12 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e[Ie] rated operational current:\u003c\/th\u003e\n\u003ctd\u003e 12 A at 12 A at 500 V9 A at 690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUtilisation category:\u003c\/th\u003e\n\u003ctd\u003e AC-43AC-44AC-41\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e[Ics] rated service breaking capacity:\u003c\/th\u003e\n\u003ctd\u003e 50 kA at 230 V50 kA at 440 V10 kA at 500 V4 kA at 690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAuxiliary contact composition:\u003c\/th\u003e\n\u003ctd\u003e 1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAuxiliary contacts type:\u003c\/th\u003e\n\u003ctd\u003e  type linked contacts (1 NO + 1 NC) conforming to IEC 60947-4-1 type mirror contact (1 NC) conforming to IEC 60947-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e[Uc] control circuit voltage:\u003c\/th\u003e\n\u003ctd\u003e 24 V AC 50\/60 Hz24 V DC48...72 V AC 50\/60 Hz48...72 V DC110...240 V AC 50\/60 Hz110...220 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"section-description\"\u003e\u003cdiv\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eTypical current consumption:\u003c\/th\u003e\n\u003ctd\u003e 130 mA at 24 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD140 mA at 24 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD150 mA at 24 V DC I maximum while closing with LUCM280 mA at 110...220 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD280 mA at 110...240 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD280 mA at 48...72 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD280 mA at 48...72 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD35 mA at 110...220 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD35 mA at 110...240 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD35 mA at 48...72 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD35 mA at 48...72 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD60 mA at 24 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD70 mA at 24 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD70 mA at 24 V DC I rms sealed with LUCM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeat dissipation:\u003c\/th\u003e\n\u003ctd\u003e 2 W for control circuit with LUCA, LUCB, LUCC, LUCD1.7 W for control circuit with LUCM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety reliability level:\u003c\/th\u003e\n\u003ctd\u003e B10d = 1369863 cycles contactor with nominal load conforming to EN\/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load conforming to EN\/ISO 13849-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating time:\u003c\/th\u003e\n\u003ctd\u003e 35 ms opening with LUCA, LUCB, LUCC, LUCD, LUCM for control circuit50 ms at \u0026gt;= 72 V closing with LUCA, LUCB, LUCC, LUCD for control circuit60 ms at 48 V closing with LUCA, LUCB, LUCC, LUCD for control circuit70 ms at 24 V closing with LUCA, LUCB, LUCC, LUCD for control circuit75 ms closing with LUCM for control circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMechanical durability:\u003c\/th\u003e\n\u003ctd\u003e 15 Mcycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum operating rate:\u003c\/th\u003e\n\u003ctd\u003e 3600 cyc\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct certifications:\u003c\/th\u003e\n\u003ctd\u003e CEULCSACCCEACASEFAATEXMarine\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandards:\u003c\/th\u003e\n\u003ctd\u003e EN 60947-6-2IEC 60947-6-2UL 60947-4-1, with phase barrierCSA C22.2 No 60947-4-1, with phase barrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e[Ui] rated insulation voltage:\u003c\/th\u003e\n\u003ctd\u003e 690 V conforming to IEC 60947-6-2 (pollution degree 3)600 V conforming to UL 60947-4-1600 V conforming to CSA C22.2 No 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e[Uimp] rated impulse withstand voltage:\u003c\/th\u003e\n\u003ctd\u003e 6 kV conforming to IEC 60947-6-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafe separation of circuit:\u003c\/th\u003e\n\u003ctd\u003e 400 V SELV between the control and auxiliary circuits conforming to IEC 60947-1 appendix N400 V SELV between the control or auxiliary circuit and the main circuit conforming to IEC 60947-1 appendix N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFixing mode:\u003c\/th\u003e\n\u003ctd\u003e Clipped (DIN rail)Screw-fixed (plate)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnections - terminals:\u003c\/th\u003e\n\u003ctd\u003e Power circuit: screw clamp terminals 1 cable(s) 1...10 mm² rigidPower circuit: screw clamp terminals 1 cable(s) 1...6 mm² flexible with cable endPower circuit: screw clamp terminals 1 cable(s) 2.5...10 mm² flexible without cable endPower circuit: screw clamp terminals 2 cable(s) 1...6 mm² flexible with cable endPower circuit: screw clamp terminals 2 cable(s) 1...6 mm² rigidPower circuit: screw clamp terminals 2 cable(s) 1.5...6 mm² flexible without cable endControl circuit: without connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTightening torque:\u003c\/th\u003e\n\u003ctd\u003e Control circuit: 0.8...1.2 N.m flat screwdriver 5 mmControl circuit: 0.8...1.2 N.m Philips no 1 screwdriver 5 mmPower circuit: 1.9...2.5 N.m flat screwdriver 6 mmPower circuit: 1.9...2.5 N.m Philips No 2 screwdriver 6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth:\u003c\/th\u003e\n\u003ctd\u003e 45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight:\u003c\/th\u003e\n\u003ctd\u003e 154 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDepth:\u003c\/th\u003e\n\u003ctd\u003e 126 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight:\u003c\/th\u003e\n\u003ctd\u003e 0.865 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCompatibility code:\u003c\/th\u003e\n\u003ctd\u003e LUB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\n\u003cdiv class=\"section-additional\"\u003e\u003cdiv\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eIP degree of protection:\u003c\/th\u003e\n\u003ctd\u003e IP20 conforming to IEC 60947-1 (front panel and wired terminals)IP20 conforming to IEC 60947-1 (other faces)IP40 conforming to IEC 60947-1 (front panel outside connection zone)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtective treatment:\u003c\/th\u003e\n\u003ctd\u003e TH conforming to IEC 60068\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient air temperature for operation:\u003c\/th\u003e\n\u003ctd\u003e -25...60 °C with LUCM-25...70 °C with LUCA, LUCB, LUCC, LUCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient air temperature for storage:\u003c\/th\u003e\n\u003ctd\u003e -40...85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFire resistance:\u003c\/th\u003e\n\u003ctd\u003e 960 °C parts supporting live components conforming to IEC 60695-2-12650 °C conforming to IEC 60695-2-12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating altitude:\u003c\/th\u003e\n\u003ctd\u003e 2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShock resistance:\u003c\/th\u003e\n\u003ctd\u003e 10 gn power poles open conforming to IEC 60068-2-2715 gn power poles closed conforming to IEC 60068-2-27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVibration resistance:\u003c\/th\u003e\n\u003ctd\u003e 2 gn (f= 5...300 Hz) power poles open conforming to IEC 60068-2-274 gn (f= 5...300 Hz) power poles closed conforming to IEC 60068-2-27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eResistance to electrostatic discharge:\u003c\/th\u003e\n\u003ctd\u003e 8 kV level 3 in open air conforming to IEC 61000-4-28 kV level 4 on contact conforming to IEC 61000-4-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eResistance to radiated fields:\u003c\/th\u003e\n\u003ctd\u003e 10 V\/m 3 conforming to IEC 61000-4-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eResistance to fast transients:\u003c\/th\u003e\n\u003ctd\u003e 2 kV class 3 serial link conforming to IEC 61000-4-44 kV class 4 all circuits except for serial link conforming to IEC 61000-4-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNon-dissipating shock wave:\u003c\/th\u003e\n\u003ctd\u003e 1 kV serial mode 24...240 V AC conforming to IEC 60947-6-21 kV serial mode 48...220 V DC conforming to IEC 60947-6-22 kV common mode 24...240 V AC conforming to IEC 60947-6-22 kV common mode 48...220 V DC conforming to IEC 60947-6-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eImmunity to radioelectric fields:\u003c\/th\u003e\n\u003ctd\u003e 10 V conforming to IEC 61000-4-6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eImmunity to microbreaks:\u003c\/th\u003e\n\u003ctd\u003e 3 ms for control circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eImmunity to voltage dips:\u003c\/th\u003e\n\u003ctd\u003e 70 % \/ 500 ms conforming to IEC 61000-4-11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSustainable offer status:\u003c\/th\u003e\n\u003ctd\u003e Green Premium productREACh Regulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\n\u003cdiv class=\"table-wrapper\" id=\"product-attributes\"\u003e\u003ctable class=\"additional-attributes w-full text-xs lg:text-xl\"\u003e \u003ctr class=\"\"\u003e\n\u003cth class=\"col label w-5\/12 lg:w-1\/4 py-1.5 text-left text-gray-600 font-normal align-top product-attribute-label\" scope=\"row\"\u003eCode EAN:\u003c\/th\u003e\n\u003ctd class=\"col data w-7\/12 lg:w-3\/4 py-1.5 pl-2 lg:pl-20 text-left product-attribute-value\" data-th=\"Code EAN\"\u003e3389110362794\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":44208520724534,"sku":"LUB120","price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0698\/4712\/1974\/files\/LUB120.png?v=1760102278","url":"https:\/\/www.tehonet.fi\/products\/schneider-electric-advanced-power-base-tesys-u-3p-12a-690v-lub120","provider":"TEHONET Power Electronics, Electrical \u0026 Automation equipment and components","version":"1.0","type":"link"}