{"product_id":"schneider-electric-circuit-breaker-basic-frame-compact-nsx630h-70-ka-at-415-vac-50-60-hz-630-a-without-trip-unit-3-poles-c63h3","title":"circuit breaker basic frame, ComPacT NSX630H, 70 kA at 415 VAC 50\/60 Hz, 630 A, without trip unit, 3 poles - C63H3","description":"\u003cdiv class=\"section-product-attributes\"\u003e \u003cdiv\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eRange:\u003c\/th\u003e\n\u003ctd\u003e ComPacT new generation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRange of product:\u003c\/th\u003e\n\u003ctd\u003e ComPacT NSX400...630 new generation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct name:\u003c\/th\u003e\n\u003ctd\u003e ComPacT NSX new generation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDevice short name:\u003c\/th\u003e\n\u003ctd\u003e NSX630H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct or component type:\u003c\/th\u003e\n\u003ctd\u003e Basic frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDevice application:\u003c\/th\u003e\n\u003ctd\u003e Distribution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePoles description:\u003c\/th\u003e\n\u003ctd\u003e 3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e[In] rated current:\u003c\/th\u003e\n\u003ctd\u003e 630 A at 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e[Ue] rated operational voltage:\u003c\/th\u003e\n\u003ctd\u003e 690 V AC 50\/60 Hz conforming to IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNetwork type:\u003c\/th\u003e\n\u003ctd\u003e AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNetwork frequency:\u003c\/th\u003e\n\u003ctd\u003e 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSuitability for isolation:\u003c\/th\u003e\n\u003ctd\u003e Yes conforming to EN\/IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUtilisation category:\u003c\/th\u003e\n\u003ctd\u003e Category A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBreaking capacity:\u003c\/th\u003e\n\u003ctd\u003e 85 kA at 240 V AC 50\/60 Hz conforming to UL 50865 kA at 480 V AC 50\/60 Hz conforming to UL 508100 kA Icu at 220\/240 V AC 50\/60 Hz conforming to IEC 60947-235 kA Icu at 525 V AC 50\/60 Hz conforming to IEC 60947-250 kA Icu at 500 V AC 50\/60 Hz conforming to IEC 60947-265 kA Icu at 440 V AC 50\/60 Hz conforming to IEC 60947-270 kA Icu at 380\/415 V AC 50\/60 Hz conforming to IEC 60947-220 kA Icu at 660\/690 V AC 50\/60 Hz conforming to IEC 60947-220 kA at 600 V AC 50\/60 Hz conforming to UL 508\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBreaking capacity code:\u003c\/th\u003e\n\u003ctd\u003e H 70 kA 415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eControl type:\u003c\/th\u003e\n\u003ctd\u003e Toggle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting mode:\u003c\/th\u003e\n\u003ctd\u003e Fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"section-description\"\u003e\u003cdiv\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003e[Ui] rated insulation voltage:\u003c\/th\u003e\n\u003ctd\u003e 800 V AC 50\/60 Hz conforming to IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e[Uimp] rated impulse withstand voltage:\u003c\/th\u003e\n\u003ctd\u003e 8 kV conforming to IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e[Ics] rated service breaking capacity:\u003c\/th\u003e\n\u003ctd\u003e 11 kA at 525 V AC 50\/60 Hz conforming to IEC 60947-210 kA at 660\/690 V AC 50\/60 Hz conforming to IEC 60947-2100 kA at 220\/240 V AC 50\/60 Hz conforming to IEC 60947-250 kA at 500 V AC 50\/60 Hz conforming to IEC 60947-265 kA at 440 V AC 50\/60 Hz conforming to IEC 60947-270 kA at 380\/415 V AC 50\/60 Hz conforming to IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMechanical durability:\u003c\/th\u003e\n\u003ctd\u003e 15000 cycles conforming to IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical durability:\u003c\/th\u003e\n\u003ctd\u003e 6000 cycles 690 V AC 50\/60 Hz In\/2 conforming to IEC 60947-22000 cycles 690 V AC 50\/60 Hz In conforming to IEC 60947-24000 cycles 440 V AC 50\/60 Hz In conforming to IEC 60947-28000 cycles 440 V AC 50\/60 Hz In\/2 conforming to IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting support:\u003c\/th\u003e\n\u003ctd\u003e Backplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUpside connection:\u003c\/th\u003e\n\u003ctd\u003e Front\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDownside connection:\u003c\/th\u003e\n\u003ctd\u003e Front\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnection pitch:\u003c\/th\u003e\n\u003ctd\u003e 45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection type:\u003c\/th\u003e\n\u003ctd\u003e Without protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth:\u003c\/th\u003e\n\u003ctd\u003e 140 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight:\u003c\/th\u003e\n\u003ctd\u003e 255 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDepth:\u003c\/th\u003e\n\u003ctd\u003e 110 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCompatibility code:\u003c\/th\u003e\n\u003ctd\u003e NSX630\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\n\u003cdiv class=\"section-additional\"\u003e\u003cdiv\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eStandards:\u003c\/th\u003e\n\u003ctd\u003e EN\/IEC 60947-2UL 508\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct certifications:\u003c\/th\u003e\n\u003ctd\u003e CSAUL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePollution degree:\u003c\/th\u003e\n\u003ctd\u003e 3 conforming to IEC 60664-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIP degree of protection:\u003c\/th\u003e\n\u003ctd\u003e IP40 conforming to IEC 60529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIK degree of protection:\u003c\/th\u003e\n\u003ctd\u003e IK07 conforming to IEC 62262\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient air temperature for operation:\u003c\/th\u003e\n\u003ctd\u003e -25...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient air temperature for storage:\u003c\/th\u003e\n\u003ctd\u003e -50...85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eREACh Regulation:\u003c\/th\u003e\n\u003ctd\u003e Reference contains Substances of Very High Concern above the thresholdEU RoHS Directive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\n\u003cdiv class=\"table-wrapper\" id=\"product-attributes\"\u003e\u003ctable class=\"additional-attributes w-full text-xs lg:text-xl\"\u003e \u003ctr class=\"\"\u003e\n\u003cth class=\"col label w-5\/12 lg:w-1\/4 py-1.5 text-left text-gray-600 font-normal align-top product-attribute-label\" scope=\"row\"\u003eCode EAN:\u003c\/th\u003e\n\u003ctd class=\"col data w-7\/12 lg:w-3\/4 py-1.5 pl-2 lg:pl-20 text-left product-attribute-value\" data-th=\"Code EAN\"\u003e3606482002982\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":44208545136694,"sku":"C63H3","price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0698\/4712\/1974\/files\/C63H3.png?v=1760102696","url":"https:\/\/www.tehonet.fi\/products\/schneider-electric-circuit-breaker-basic-frame-compact-nsx630h-70-ka-at-415-vac-50-60-hz-630-a-without-trip-unit-3-poles-c63h3","provider":"TEHONET Power Electronics, Electrical \u0026 Automation equipment and components","version":"1.0","type":"link"}