{"product_id":"schneider-electric-circuit-breaker-compact-nsx100r-200-ka-at-415-vac-micrologic-6-2-e-m-trip-unit-80-a-3-poles-3d-c10r36m080","title":"circuit breaker ComPacT NSX100R, 200 kA at 415 VAC, MicroLogic 6.2 E-M trip unit 80 A, 3 poles 3d - C10R36M080","description":"\u003cdiv class=\"section-product-attributes\"\u003e \u003cdiv\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eRange:\u003c\/th\u003e\n\u003ctd\u003e ComPacT new generation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct name:\u003c\/th\u003e\n\u003ctd\u003e ComPacT NSX new generation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRange of product:\u003c\/th\u003e\n\u003ctd\u003e ComPacT NSX100...250 new generation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDevice short name:\u003c\/th\u003e\n\u003ctd\u003e NSX100R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct or component type:\u003c\/th\u003e\n\u003ctd\u003e Circuit breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDevice application:\u003c\/th\u003e\n\u003ctd\u003e Motor protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePoles description:\u003c\/th\u003e\n\u003ctd\u003e 3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtected poles description:\u003c\/th\u003e\n\u003ctd\u003e 3D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e[In] rated current:\u003c\/th\u003e\n\u003ctd\u003e 80 A at 65 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e[Ue] rated operational voltage:\u003c\/th\u003e\n\u003ctd\u003e 690 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNetwork type:\u003c\/th\u003e\n\u003ctd\u003e AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNetwork frequency:\u003c\/th\u003e\n\u003ctd\u003e 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSuitability for isolation:\u003c\/th\u003e\n\u003ctd\u003e Yes conforming to EN\/IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUtilisation category:\u003c\/th\u003e\n\u003ctd\u003e Category A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBreaking capacity:\u003c\/th\u003e\n\u003ctd\u003e 200 kA Icu at 220\/240 V AC 50\/60 Hz conforming to IEC 60947-2200 kA Icu at 380\/415 V AC 50\/60 Hz conforming to IEC 60947-2200 kA Icu at 440 V AC 50\/60 Hz conforming to IEC 60947-280 kA Icu at 500 V AC 50\/60 Hz conforming to IEC 60947-265 kA Icu at 525 V AC 50\/60 Hz conforming to IEC 60947-245 kA Icu at 660\/690 V AC 50\/60 Hz conforming to IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBreaking capacity code:\u003c\/th\u003e\n\u003ctd\u003e R 200 kA 415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTrip unit name:\u003c\/th\u003e\n\u003ctd\u003e Micrologic 6.2 E-M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTrip unit technology:\u003c\/th\u003e\n\u003ctd\u003e Electronic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTrip unit protection functions:\u003c\/th\u003e\n\u003ctd\u003e LSIG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eControl type:\u003c\/th\u003e\n\u003ctd\u003e Toggle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting mode:\u003c\/th\u003e\n\u003ctd\u003e Fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"section-description\"\u003e\u003cdiv\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003e[Ui] rated insulation voltage:\u003c\/th\u003e\n\u003ctd\u003e 800 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e[Uimp] rated impulse withstand voltage:\u003c\/th\u003e\n\u003ctd\u003e 8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e[Ics] rated service breaking capacity:\u003c\/th\u003e\n\u003ctd\u003e 200 kA at 220\/240 V AC 50\/60 Hz conforming to IEC 60947-2200 kA at 380\/415 V AC 50\/60 Hz conforming to IEC 60947-2200 kA at 440 V AC 50\/60 Hz conforming to IEC 60947-280 kA at 500 V AC 50\/60 Hz conforming to IEC 60947-265 kA at 525 V AC 50\/60 Hz conforming to IEC 60947-245 kA at 660\/690 V AC 50\/60 Hz conforming to IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMechanical durability:\u003c\/th\u003e\n\u003ctd\u003e 20000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical durability:\u003c\/th\u003e\n\u003ctd\u003e 20000 cycles at 440 V In\/210000 cycles at 440 V In10000 cycles at 690 V In\/25000 cycles at 690 V In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower dissipation per pole:\u003c\/th\u003e\n\u003ctd\u003e 3.01 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting support:\u003c\/th\u003e\n\u003ctd\u003e Backplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting position:\u003c\/th\u003e\n\u003ctd\u003e Horizontal and verticalFlat on the back\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUpside connection:\u003c\/th\u003e\n\u003ctd\u003e Front\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDownside connection:\u003c\/th\u003e\n\u003ctd\u003e Front\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnection pitch:\u003c\/th\u003e\n\u003ctd\u003e 35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection type:\u003c\/th\u003e\n\u003ctd\u003e L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTrip unit rating:\u003c\/th\u003e\n\u003ctd\u003e 80 A at 65 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor tripping class:\u003c\/th\u003e\n\u003ctd\u003e 5302010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eComplementary motor protection:\u003c\/th\u003e\n\u003ctd\u003e Stalled rotorPhase unbalanceProtracted starting timeUnderload\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLong time pick-up adjustment type Ir:\u003c\/th\u003e\n\u003ctd\u003e Adjustable 9 settings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLong time pick-up adjustment range:\u003c\/th\u003e\n\u003ctd\u003e 35...80 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLong time delay adjustment type:\u003c\/th\u003e\n\u003ctd\u003e Adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e[tr] long-time delay adjustment range:\u003c\/th\u003e\n\u003ctd\u003e 120 s at 1.5 x Ir for trip class 56.5 s at 6 x Ir for trip class 55 s at 7.2 x Ir for trip class 5240 s at 1.5 x Ir for trip class 1013.5 s at 6 x Ir for trip class 1010 s at 7.2 x Ir for trip class 10480 s at 1.5 x Ir for trip class 2026 s at 6 x Ir for trip class 2020 s at 7.2 x Ir for trip class 20720 s at 1.5 x Ir for trip class 3038 s at 6 x Ir for trip class 3030 s at 7.2 x Ir for trip class 30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eThermal memory:\u003c\/th\u003e\n\u003ctd\u003e 20 minutes before and after tripping\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShort-time pick-up adjustment type Isd:\u003c\/th\u003e\n\u003ctd\u003e Adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e[Isd] short-time pick-up adjustment range:\u003c\/th\u003e\n\u003ctd\u003e 5...13 x Ir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShort-time delay adjustment type:\u003c\/th\u003e\n\u003ctd\u003e Fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstantaneous pick-up adjustment type Ii:\u003c\/th\u003e\n\u003ctd\u003e Fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstantaneous pick-up adjustment range:\u003c\/th\u003e\n\u003ctd\u003e 1200 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGround-fault pick-up adjustment type:\u003c\/th\u003e\n\u003ctd\u003e Adjustable 9 settings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e[Ig] ground-fault pick-up adjustment range:\u003c\/th\u003e\n\u003ctd\u003e 0.2...1 x InIg enable on\/off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGround-fault time delay adjustment type -tg:\u003c\/th\u003e\n\u003ctd\u003e Adjustable 5 settings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e[tg] ground-fault time delay adjustment range:\u003c\/th\u003e\n\u003ctd\u003e 0...0.4 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEarth-leakage protection:\u003c\/th\u003e\n\u003ctd\u003e Without\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eZone selective interlocking ZSI:\u003c\/th\u003e\n\u003ctd\u003e With\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of slots:\u003c\/th\u003e\n\u003ctd\u003e 5 slot(s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLocal signalling:\u003c\/th\u003e\n\u003ctd\u003e Flashing LED (green) for ready to operateLED 95 % Ith (red) for temperature over set point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay type:\u003c\/th\u003e\n\u003ctd\u003e LCD display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of measurement:\u003c\/th\u003e\n\u003ctd\u003e Energy meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication of data:\u003c\/th\u003e\n\u003ctd\u003e Power qualityDemand current and powerTime-stamped histories and event tablesProtection and alarm settingsInstantaneous and demand valuesThermal image functionMaximeters\/minimetersPhase sequenceMaintenance indicatorsEnergy metering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth:\u003c\/th\u003e\n\u003ctd\u003e 105 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight:\u003c\/th\u003e\n\u003ctd\u003e 161 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDepth:\u003c\/th\u003e\n\u003ctd\u003e 86 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNet weight:\u003c\/th\u003e\n\u003ctd\u003e 2.05 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCompatibility code:\u003c\/th\u003e\n\u003ctd\u003e NSX100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\n\u003cdiv class=\"section-additional\"\u003e\u003cdiv\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eStandards:\u003c\/th\u003e\n\u003ctd\u003e EN\/IEC 60947\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct certifications:\u003c\/th\u003e\n\u003ctd\u003e EACCCCMarine\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOvervoltage category:\u003c\/th\u003e\n\u003ctd\u003e Class II\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical shock protection class:\u003c\/th\u003e\n\u003ctd\u003e Class II\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePollution degree:\u003c\/th\u003e\n\u003ctd\u003e 3 conforming to IEC 60664-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIP degree of protection:\u003c\/th\u003e\n\u003ctd\u003e IP40 conforming to IEC 60529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIK degree of protection:\u003c\/th\u003e\n\u003ctd\u003e IK07 conforming to IEC 62262\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient air temperature for operation:\u003c\/th\u003e\n\u003ctd\u003e -25...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient air temperature for storage:\u003c\/th\u003e\n\u003ctd\u003e -40...85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative humidity:\u003c\/th\u003e\n\u003ctd\u003e 0...95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating altitude:\u003c\/th\u003e\n\u003ctd\u003e 0...2000 m without derating2000 m...5000 m with derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSustainable offer status:\u003c\/th\u003e\n\u003ctd\u003e Green Premium productREACh Regulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\n\u003cdiv class=\"table-wrapper\" id=\"product-attributes\"\u003e\u003ctable class=\"additional-attributes w-full text-xs lg:text-xl\"\u003e \u003ctr class=\"\"\u003e\n\u003cth class=\"col label w-5\/12 lg:w-1\/4 py-1.5 text-left text-gray-600 font-normal align-top product-attribute-label\" scope=\"row\"\u003eCode EAN:\u003c\/th\u003e\n\u003ctd class=\"col data w-7\/12 lg:w-3\/4 py-1.5 pl-2 lg:pl-20 text-left product-attribute-value\" data-th=\"Code EAN\"\u003e3606482001459\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":44208577314870,"sku":"C10R36M080","price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0698\/4712\/1974\/files\/C10R36M080.png?v=1760103049","url":"https:\/\/www.tehonet.fi\/products\/schneider-electric-circuit-breaker-compact-nsx100r-200-ka-at-415-vac-micrologic-6-2-e-m-trip-unit-80-a-3-poles-3d-c10r36m080","provider":"TEHONET Power Electronics, Electrical \u0026 Automation equipment and components","version":"1.0","type":"link"}