{"product_id":"schneider-electric-controller-m221-16-io-relay-ethernet-tm221me16r","title":"controller M221 16 IO relay Ethernet - TM221ME16R","description":"\u003cdiv class=\"section-product-attributes\"\u003e \u003cdiv\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eRange of product:\u003c\/th\u003e\n\u003ctd\u003e Modicon M221\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct or component type:\u003c\/th\u003e\n\u003ctd\u003e Logic controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e[Us] rated supply voltage:\u003c\/th\u003e\n\u003ctd\u003e 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiscrete input number:\u003c\/th\u003e\n\u003ctd\u003e 8, discrete input conforming to IEC 61131-2 Type 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAnalogue input number:\u003c\/th\u003e\n\u003ctd\u003e 2 at 0...10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiscrete output type:\u003c\/th\u003e\n\u003ctd\u003e Relay normally open\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiscrete output number:\u003c\/th\u003e\n\u003ctd\u003e 8 relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiscrete output voltage:\u003c\/th\u003e\n\u003ctd\u003e 5...125 V DC5...250 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiscrete output current:\u003c\/th\u003e\n\u003ctd\u003e 2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"section-description\"\u003e\u003cdiv\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eDiscrete I\/O number:\u003c\/th\u003e\n\u003ctd\u003e 16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum number of I\/O expansion module:\u003c\/th\u003e\n\u003ctd\u003e 7 for relay output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupply voltage limits:\u003c\/th\u003e\n\u003ctd\u003e 20.4...28.8 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInrush current:\u003c\/th\u003e\n\u003ctd\u003e 35 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum power consumption in W:\u003c\/th\u003e\n\u003ctd\u003e 23.3 W at 24 V (with max number of I\/O expansion module)4.3 W at 24 V (without I\/O expansion module)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply output current:\u003c\/th\u003e\n\u003ctd\u003e 0.52 A 5 V for expansion bus0.46 A 24 V for expansion bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiscrete input logic:\u003c\/th\u003e\n\u003ctd\u003e Sink or source (positive\/negative)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiscrete input voltage:\u003c\/th\u003e\n\u003ctd\u003e 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiscrete input voltage type:\u003c\/th\u003e\n\u003ctd\u003e DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAnalogue input resolution:\u003c\/th\u003e\n\u003ctd\u003e 10 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLSB value:\u003c\/th\u003e\n\u003ctd\u003e 10 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConversion time:\u003c\/th\u003e\n\u003ctd\u003e 1 ms per channel + 1 controller cycle time for analogue input analog input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePermitted overload on inputs:\u003c\/th\u003e\n\u003ctd\u003e +\/- 30 V DC for 5 min (maximum) for analog input+\/- 13 V DC (permanent) for analog input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage state 1 guaranteed:\u003c\/th\u003e\n\u003ctd\u003e \u0026gt;= 15 V for input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage state 0 guaranteed:\u003c\/th\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiscrete input current:\u003c\/th\u003e\n\u003ctd\u003e 7 mA for discrete input5 mA for fast input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput impedance:\u003c\/th\u003e\n\u003ctd\u003e 100 kOhm for analog input3.4 kOhm for input4.9 kOhm for fast input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eResponse time:\u003c\/th\u003e\n\u003ctd\u003e 35 µs turn-off, I2...I5 terminal(s) for input5 µs turn-on, I0, I1, I6, I7 terminal(s) for fast input35 µs turn-on, other terminals terminal(s) for input5 µs turn-off, I0, I1, I6, I7 terminal(s) for fast input100 µs turn-off, other terminals terminal(s) for input5 µs turn-on, turn-off, Q0...Q1 terminal(s) for output50 µs turn-on, turn-off, Q2...Q3 terminal(s) for output300 µs turn-on, turn-off, other terminals terminal(s) for output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConfigurable filtering time:\u003c\/th\u003e\n\u003ctd\u003e 0 ms for input3 ms for input12 ms for input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput voltage limits:\u003c\/th\u003e\n\u003ctd\u003e 125 V DC277 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum current per output common:\u003c\/th\u003e\n\u003ctd\u003e 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAbsolute accuracy error:\u003c\/th\u003e\n\u003ctd\u003e +\/- 1 % of full scale for analog input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical durability:\u003c\/th\u003e\n\u003ctd\u003e 100000 cycles AC-12, 120 V, 240 VA, resistive100000 cycles AC-12, 240 V, 480 VA, resistive300000 cycles AC-12, 120 V, 80 VA, resistive300000 cycles AC-12, 240 V, 160 VA, resistive100000 cycles AC-15, cos phi = 0.35, 120 V, 60 VA, inductive100000 cycles AC-15, cos phi = 0.35, 240 V, 120 VA, inductive300000 cycles AC-15, cos phi = 0.35, 120 V, 18 VA, inductive300000 cycles AC-15, cos phi = 0.35, 240 V, 36 VA, inductive100000 cycles AC-14, cos phi = 0.7, 120 V, 120 VA, inductive100000 cycles AC-14, cos phi = 0.7, 240 V, 240 VA, inductive300000 cycles AC-14, cos phi = 0.7, 120 V, 36 VA, inductive300000 cycles AC-14, cos phi = 0.7, 240 V, 72 VA, inductive100000 cycles DC-12, 24 V, 48 W, resistive300000 cycles DC-12, 24 V, 16 W, resistive100000 cycles DC-13, 24 V, 24 W, inductive (L\/R = 7 ms)300000 cycles DC-13, 24 V, 7.2 W, inductive (L\/R = 7 ms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching frequency:\u003c\/th\u003e\n\u003ctd\u003e 20 switching operations\/minute with maximum load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMechanical durability:\u003c\/th\u003e\n\u003ctd\u003e 20000000 cycles for relay output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMinimum load:\u003c\/th\u003e\n\u003ctd\u003e 1 mA at 5 V DC for relay output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection type:\u003c\/th\u003e\n\u003ctd\u003e Without protection at 5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReset time:\u003c\/th\u003e\n\u003ctd\u003e 1 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMemory capacity:\u003c\/th\u003e\n\u003ctd\u003e 256 kB for user application and data RAM with 10000 instructions256 kB for internal variables RAM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eData backed up:\u003c\/th\u003e\n\u003ctd\u003e 256 kB built-in flash memory for backup of application and data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eData storage equipment:\u003c\/th\u003e\n\u003ctd\u003e 2 GB SD card (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBattery type:\u003c\/th\u003e\n\u003ctd\u003e BR2032 lithium non-rechargeable, battery life: 4 year(s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBackup time:\u003c\/th\u003e\n\u003ctd\u003e 1 year at 25 °C (by interruption of power supply)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExecution time for 1 KInstruction:\u003c\/th\u003e\n\u003ctd\u003e 0.3 ms for event and periodic task0.7 ms for other instruction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExecution time per instruction:\u003c\/th\u003e\n\u003ctd\u003e 0.2 µs Boolean\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExct time for event task:\u003c\/th\u003e\n\u003ctd\u003e 60 µs response time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApplication structure:\u003c\/th\u003e\n\u003ctd\u003e 1 configurable freewheeling\/cyclic master task1 cyclic auxiliary task8 interrupt tasks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum size of object areas:\u003c\/th\u003e\n\u003ctd\u003e 512 %KW constant words255 %C counters8000 %MW memory words255 %TM timers512 %M memory bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRealtime clock:\u003c\/th\u003e\n\u003ctd\u003e With\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eClock drift:\u003c\/th\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRegulation loop:\u003c\/th\u003e\n\u003ctd\u003e Adjustable PID regulator up to 14 simultaneous loops\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFunction available:\u003c\/th\u003e\n\u003ctd\u003e Frequency generatorPWMPLS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCounting input number:\u003c\/th\u003e\n\u003ctd\u003e 4 fast input (HSC mode) at 100 kHz 32 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eControl signal type:\u003c\/th\u003e\n\u003ctd\u003e Single phaseA\/BPulse\/direction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIntegrated connection type:\u003c\/th\u003e\n\u003ctd\u003e USB port with mini B USB 2.0 connectorNon isolated serial link serial 1 with RJ45 connector and RS232\/RS485 interface Ethernet with RJ45 connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupply:\u003c\/th\u003e\n\u003ctd\u003e  (serial 1)serial link supply: 5 V, \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTransmission rate:\u003c\/th\u003e\n\u003ctd\u003e 1.2...115.2 kbit\/s (115.2 kbit\/s by default) for bus length of 15 m for RS4851.2...115.2 kbit\/s (115.2 kbit\/s by default) for bus length of 3 m for RS232480 Mbit\/s for USB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication port protocol:\u003c\/th\u003e\n\u003ctd\u003e USB port: USB - SoMachine-NetworkNon isolated serial link: Modbus master\/slave - RTU\/ASCII or SoMachine-NetworkEthernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePort Ethernet:\u003c\/th\u003e\n\u003ctd\u003e 10BASE-T\/100BASE-TX 1 port with 100 m copper cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication service:\u003c\/th\u003e\n\u003ctd\u003e DHCP clientModbus TCP slave deviceEthernet\/IP adapterModbus TCP clientModbus TCP server\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLocal signalling:\u003c\/th\u003e\n\u003ctd\u003e 1 LED (green) for PWR1 LED (green) for RUN1 LED (red) for module error (ERR)1 LED (green) for SD card access (SD)1 LED (red) for BAT1 LED per channel (green) for I\/O state1 LED (green) for SLEthernet network activity (green) for ACTEthernet network link (yellow) for Link (Link Status)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical connection:\u003c\/th\u003e\n\u003ctd\u003e  terminal block, 3 terminal(s) for connecting the 24 V DC power supply connector, 4 terminal(s) for analogue inputsMini B USB 2.0 connector for a programming terminal removable screw terminal block, 10 terminal(s) for inputs removable screw terminal block, 11 terminal(s) for outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum cable distance between devices:\u003c\/th\u003e\n\u003ctd\u003e Shielded cable: Unshielded cable: Unshielded cable: Unshielded cable: Shielded cable: \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsulation:\u003c\/th\u003e\n\u003ctd\u003e Between input and internal logic at 500 V ACBetween fast input and internal logic at 500 V ACNon-insulated between inputsBetween output and internal logic at 500 V ACBetween output groups at 500 V ACNon-insulated between analogue input and internal logicNon-insulated between analogue inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMarking:\u003c\/th\u003e\n\u003ctd\u003e CE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting support:\u003c\/th\u003e\n\u003ctd\u003e Top hat type TH35-15 rail conforming to IEC 60715Top hat type TH35-7.5 rail conforming to IEC 60715 plate or panel with fixing kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight:\u003c\/th\u003e\n\u003ctd\u003e 90 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDepth:\u003c\/th\u003e\n\u003ctd\u003e 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth:\u003c\/th\u003e\n\u003ctd\u003e 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight:\u003c\/th\u003e\n\u003ctd\u003e 0.264 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\n\u003cdiv aria-labelledby=\"trigger-product.additional\" class=\"pb-6 lg:pb-10 hidden\" id=\"section-product.additional\" role=\"region\" :class=\"{ '!block': open, '!hidden': !open }\"\u003e \u003cdiv class=\"product attribute wysiwyg\" x-ignore=\"\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eStandards:\u003c\/th\u003e\n\u003ctd\u003e EN\/IEC 61010-2-201EN\/IEC 61131-2EN\/IEC 60664-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct certifications:\u003c\/th\u003e\n\u003ctd\u003e LRcULusCSADNV-GLRCMEACABSIACS E10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnvironmental characteristic:\u003c\/th\u003e\n\u003ctd\u003e Ordinary and hazardous location\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eResistance to electrostatic discharge:\u003c\/th\u003e\n\u003ctd\u003e 8 kV in air conforming to EN\/IEC 61000-4-24 kV on contact conforming to EN\/IEC 61000-4-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eResistance to electromagnetic fields:\u003c\/th\u003e\n\u003ctd\u003e 10 V\/m 80 MHz...1 GHz conforming to EN\/IEC 61000-4-33 V\/m 1.4 GHz...2 GHz conforming to EN\/IEC 61000-4-31 V\/m 2...2.7 GHz conforming to EN\/IEC 61000-4-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eResistance to magnetic fields:\u003c\/th\u003e\n\u003ctd\u003e 30 A\/m 50\/60 Hz conforming to EN\/IEC 61000-4-8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eResistance to fast transients:\u003c\/th\u003e\n\u003ctd\u003e 2 kV (power lines) conforming to EN\/IEC 61000-4-42 kV (relay output) conforming to EN\/IEC 61000-4-41 kV (I\/O) conforming to EN\/IEC 61000-4-41 kV (Ethernet line) conforming to EN\/IEC 61000-4-41 kV (serial link) conforming to EN\/IEC 61000-4-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSurge withstand:\u003c\/th\u003e\n\u003ctd\u003e 2 kV power lines (AC) common mode conforming to EN\/IEC 61000-4-52 kV relay output common mode conforming to EN\/IEC 61000-4-51 kV I\/O common mode conforming to EN\/IEC 61000-4-51 kV shielded cable common mode conforming to EN\/IEC 61000-4-50.5 kV power lines (DC) differential mode conforming to EN\/IEC 61000-4-51 kV power lines (AC) differential mode conforming to EN\/IEC 61000-4-51 kV relay output differential mode conforming to EN\/IEC 61000-4-50.5 kV power lines (DC) common mode conforming to EN\/IEC 61000-4-5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eResistance to conducted disturbances:\u003c\/th\u003e\n\u003ctd\u003e 10 V 0.15...80 MHz conforming to EN\/IEC 61000-4-63 V 0.1...80 MHz conforming to Marine specification (LR, ABS, DNV, GL)10 V spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz) conforming to Marine specification (LR, ABS, DNV, GL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectromagnetic emission:\u003c\/th\u003e\n\u003ctd\u003e Conducted emissions - test level: 79 dB?V\/m QP\/66 dB?V\/m AV ( power lines (AC)) at 0.15...0.5 MHz conforming to EN\/IEC 55011Conducted emissions - test level: 73 dB?V\/m QP\/60 dB?V\/m AV ( power lines (AC)) at 0.5...300 MHz conforming to EN\/IEC 55011Conducted emissions - test level: 120...69 dBµV\/m QP ( power lines) at 10...150 kHz conforming to EN\/IEC 55011Conducted emissions - test level: 63 dB?V\/m QP ( power lines) at 1.5...30 MHz conforming to EN\/IEC 55011Radiated emissions - test level: 40 dB?V\/m QP class A ( 10 m) at 30...230 MHz conforming to EN\/IEC 55011Conducted emissions - test level: 79...63 dB?V\/m QP ( power lines) at 150...1500 kHz conforming to EN\/IEC 55011Radiated emissions - test level: 47 dB?V\/m QP class A ( 10 m) at 200...1000 MHz conforming to EN\/IEC 55011\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eImmunity to microbreaks:\u003c\/th\u003e\n\u003ctd\u003e 10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient air temperature for operation:\u003c\/th\u003e\n\u003ctd\u003e -10...55 °C (horizontal installation)-10...35 °C (vertical installation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient air temperature for storage:\u003c\/th\u003e\n\u003ctd\u003e -25...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative humidity:\u003c\/th\u003e\n\u003ctd\u003e 10...95 %, without condensation (in operation)10...95 %, without condensation (in storage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIP degree of protection:\u003c\/th\u003e\n\u003ctd\u003e IP20 with protective cover in place\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePollution degree:\u003c\/th\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating altitude:\u003c\/th\u003e\n\u003ctd\u003e 0...2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage altitude:\u003c\/th\u003e\n\u003ctd\u003e 0...3000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVibration resistance:\u003c\/th\u003e\n\u003ctd\u003e 3.5 mm at 5...8.4 Hz on symmetrical rail3.5 mm at 5...8.4 Hz on panel mounting1 gn at 8.4...150 Hz on symmetrical rail1 gn at 8.4...150 Hz on panel mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShock resistance:\u003c\/th\u003e\n\u003ctd\u003e 98 m\/s² for 11 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSustainable offer status:\u003c\/th\u003e\n\u003ctd\u003e Green Premium productREACh Regulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"table-wrapper\" id=\"product-attributes\" x-ignore=\"\"\u003e\u003ctable class=\"additional-attributes w-full text-xs lg:text-xl\"\u003e \u003ctr class=\"\"\u003e\n\u003cth class=\"col label w-5\/12 lg:w-1\/4 py-1.5 text-left text-gray-600 font-normal align-top product-attribute-label\" scope=\"row\"\u003eCode EAN:\u003c\/th\u003e\n\u003ctd class=\"col data w-7\/12 lg:w-3\/4 py-1.5 pl-2 lg:pl-20 text-left product-attribute-value\" data-th=\"Code EAN\"\u003e3606480611278\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":44208639180854,"sku":"TM221ME16R","price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0698\/4712\/1974\/files\/tm221me16r.png?v=1760104121","url":"https:\/\/www.tehonet.fi\/products\/schneider-electric-controller-m221-16-io-relay-ethernet-tm221me16r","provider":"TEHONET Power Electronics, Electrical \u0026 Automation equipment and components","version":"1.0","type":"link"}