{"product_id":"schneider-electric-electronic-thermal-overload-relay-tesys-giga-160-630-a-class-5e-30e-push-in-control-connection-lr9g630","title":"Electronic thermal overload relay,TeSys Giga,160-630 A,class 5E-30E,push-in control connection - LR9G630","description":"\u003cdiv class=\"section-product-attributes\"\u003e \u003cdiv\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eRange:\u003c\/th\u003e\n\u003ctd\u003e TeSys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct name:\u003c\/th\u003e\n\u003ctd\u003e TeSys LRG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct or component type:\u003c\/th\u003e\n\u003ctd\u003e Electronic thermal overload relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDevice short name:\u003c\/th\u003e\n\u003ctd\u003e LR9G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelay application:\u003c\/th\u003e\n\u003ctd\u003e Motor protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNetwork type:\u003c\/th\u003e\n\u003ctd\u003e AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eThermal overload class:\u003c\/th\u003e\n\u003ctd\u003e Class 5E...30E conforming to IEC 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eThermal protection adjustment range:\u003c\/th\u003e\n\u003ctd\u003e 160...630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"section-description\"\u003e\u003cdiv\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eNetwork frequency:\u003c\/th\u003e\n\u003ctd\u003e 30...60 Hz100 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOvervoltage category:\u003c\/th\u003e\n\u003ctd\u003e III\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTripping threshold:\u003c\/th\u003e\n\u003ctd\u003e 1.125 +\/- 0.07 In conforming to IEC 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection type:\u003c\/th\u003e\n\u003ctd\u003e Ground fault protection - tripping time adjustment: 0...1 s - for alarm circuit conforming to IEC 60947-4-1Ground fault protection - tripping time adjustment: 0...1 s - for alarm circuit conforming to UL 60947-4-1Phase loss - tripping time adjustment: 0...4 s - for alarm circuitPhase imbalance - tripping time adjustment: 0...5 s - for alarm circuit conforming to IEC 60947-4-1Phase imbalance - tripping time adjustment: 0...5 s - for alarm circuit conforming to UL 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLocal signalling:\u003c\/th\u003e\n\u003ctd\u003e LEDTrip indicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eContacts type and composition:\u003c\/th\u003e\n\u003ctd\u003e 1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e[Ith] conventional free air thermal current:\u003c\/th\u003e\n\u003ctd\u003e 5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e[Uc] control circuit voltage:\u003c\/th\u003e\n\u003ctd\u003e 24...500 V AC 50\/60 Hz24...250 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e[Ue] rated operational voltage:\u003c\/th\u003e\n\u003ctd\u003e 1000 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e[Uimp] rated impulse withstand voltage:\u003c\/th\u003e\n\u003ctd\u003e 8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReset:\u003c\/th\u003e\n\u003ctd\u003e Automatic resetManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMechanical durability:\u003c\/th\u003e\n\u003ctd\u003e 7000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSurge withstand:\u003c\/th\u003e\n\u003ctd\u003e 4 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectromagnetic compatibility:\u003c\/th\u003e\n\u003ctd\u003e EMC immunity conforming to IEC 60947-4-1Emission tests criteria A conforming to IEC 60947-4-1Immunity to radiated radio-electrical interference - test level: 20 V\/m conforming to EN\/IEC 61000-4-3Voltage dips and interruptions immunity test conforming to SEMI F47\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnections - terminals:\u003c\/th\u003e\n\u003ctd\u003e Power circuit: bar - busbar cross section: 50 x 10 mmPower circuit: lugs-ring terminals 1 300 mm²Control circuit: push-in 1 0.2...2.5 mm² - cable stiffness: solid stranded without cable endControl circuit: push-in 1 0.25...2.5 mm² - cable stiffness: flexible with cable endControl circuit: push-in 2 0.5...1.0 mm² with cable end\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTightening torque:\u003c\/th\u003e\n\u003ctd\u003e 58 N.m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting support:\u003c\/th\u003e\n\u003ctd\u003e Direct on contactorPlate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandards:\u003c\/th\u003e\n\u003ctd\u003e EN\/IEC 60947-4-1EN\/IEC 60947-5-1UL 60947-4-1CSA C22.2 No 60947-4-1JIS C8201-4-1JIS C8201-5-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct certifications:\u003c\/th\u003e\n\u003ctd\u003e CB SchemeCCCcULusUKCAATEXEU-RO-MR by DNV-GLEAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\n\u003cdiv class=\"section-additional\"\u003e\u003cdiv\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eIP degree of protection:\u003c\/th\u003e\n\u003ctd\u003e IP2X front face with shrouds conforming to IEC 60529IP2X front face with shrouds conforming to VDE 0106\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtective treatment:\u003c\/th\u003e\n\u003ctd\u003e TH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient air temperature for operation:\u003c\/th\u003e\n\u003ctd\u003e -25...60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient air temperature for storage:\u003c\/th\u003e\n\u003ctd\u003e -60...80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePermissible ambient air temperature around the device:\u003c\/th\u003e\n\u003ctd\u003e -40...60 °C at Uc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMechanical robustness:\u003c\/th\u003e\n\u003ctd\u003e Vibrations 5...300 Hz 6 gn contactor openShocks 15 gn 11 ms contactor closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient air transport temperature:\u003c\/th\u003e\n\u003ctd\u003e -25...60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight:\u003c\/th\u003e\n\u003ctd\u003e 148 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth:\u003c\/th\u003e\n\u003ctd\u003e 211 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDepth:\u003c\/th\u003e\n\u003ctd\u003e 186 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNet weight:\u003c\/th\u003e\n\u003ctd\u003e 2.67 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eColour:\u003c\/th\u003e\n\u003ctd\u003e Dark grey\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSustainable offer status:\u003c\/th\u003e\n\u003ctd\u003e Green Premium productREACh Regulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnit Type of Package 1:\u003c\/th\u003e\n\u003ctd\u003e PCENumber of Units in Package 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\n\u003cdiv class=\"table-wrapper\" id=\"product-attributes\"\u003e\u003ctable class=\"additional-attributes w-full text-xs lg:text-xl\"\u003e \u003ctr class=\"\"\u003e\n\u003cth class=\"col label w-5\/12 lg:w-1\/4 py-1.5 text-left text-gray-600 font-normal align-top product-attribute-label\" scope=\"row\"\u003eCode EAN:\u003c\/th\u003e\n\u003ctd class=\"col data w-7\/12 lg:w-3\/4 py-1.5 pl-2 lg:pl-20 text-left product-attribute-value\" data-th=\"Code EAN\"\u003e3606481912589\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":44209272651830,"sku":"LR9G630","price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0698\/4712\/1974\/files\/LR9G630.png?v=1760118973","url":"https:\/\/www.tehonet.fi\/products\/schneider-electric-electronic-thermal-overload-relay-tesys-giga-160-630-a-class-5e-30e-push-in-control-connection-lr9g630","provider":"TEHONET Power Electronics, Electrical \u0026 Automation equipment and components","version":"1.0","type":"link"}