{"product_id":"schneider-electric-estop-or-guard-harmony-xps-connected-to-supply-terminals-48-240-v-ac-dc-no-inputs-screw-xpsbac34ap","title":"Estop or guard ,Harmony XPS, connected to supply terminals 48-240 V AC\/DC , no inputs, screw - XPSBAC34AP","description":"\u003cdiv class=\"section-product-attributes\"\u003e \u003cdiv\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eRange of product:\u003c\/th\u003e\n\u003ctd\u003e Harmony Safety Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct or component type:\u003c\/th\u003e\n\u003ctd\u003e Safety module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety module name:\u003c\/th\u003e\n\u003ctd\u003e XPSBAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety module application:\u003c\/th\u003e\n\u003ctd\u003e For emergency stop and protective guard applications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFunction of module:\u003c\/th\u003e\n\u003ctd\u003e Emergency stop button with 2 NC contactsGuard monitoring with 1 or 2 limit switches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety level:\u003c\/th\u003e\n\u003ctd\u003e Can reach PL e\/category 4 for normally open relay contact conforming to ISO 13849-1Can reach SILCL 3 for normally open relay contact conforming to IEC 62061Can reach SIL 3 for normally open relay contact conforming to IEC 61508Can reach PL c\/category 1 for normally closed relay contact conforming to ISO 13849-1Can reach SILCL 1 for normally closed relay contact conforming to IEC 62061Can reach SIL 1 for normally closed relay contact conforming to IEC 61508\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety reliability data:\u003c\/th\u003e\n\u003ctd\u003e MTTFd \u0026gt; 30 years conforming to ISO 13849-1 for normally open relay contactDcavg \u0026gt;= 99 % conforming to ISO 13849-1 for normally open relay contactPFHd = 1.01E-09 conforming to ISO 13849-1 for normally open relay contactHFT = 1 conforming to IEC 62061 for normally open relay contactPFHd = 1.01E-09 conforming to IEC 62061 for normally open relay contactSFF \u0026gt; 99% conforming to IEC 62061 for normally open relay contactHFT = 1 conforming to IEC 61508-1 for normally open relay contactPFHd = 1.01E-09 conforming to IEC 61508-1 for normally open relay contactSFF \u0026gt; 99% conforming to IEC 61508-1 for normally open relay contactType = B conforming to IEC 61508-1 for normally open relay contactMTTFd \u0026gt; 30 years conforming to ISO 13849-1 for normally closed relay contactDC \u0026gt; 60 % conforming to ISO 13849-1 for normally closed relay contactPFHd = 1.01E-09 conforming to ISO 13849-1 for normally closed relay contactHFT=0 conforming to IEC 62061 for normally closed relay contactPFHd = 1.01E-09 conforming to IEC 62061 for normally closed relay contactSFF \u0026gt; 60% conforming to IEC 62061 for normally closed relay contactHFT=0 conforming to IEC 61508-1 for normally closed relay contactPFHd = 1.01E-09 conforming to IEC 61508-1 for normally closed relay contactSFF \u0026gt; 60% conforming to IEC 61508-1 for normally closed relay contactType = B conforming to IEC 61508-1 for normally closed relay contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical circuit type:\u003c\/th\u003e\n\u003ctd\u003e NC pair\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnections - terminals:\u003c\/th\u003e\n\u003ctd\u003e Removable screw terminal block, 0.2...2.5 mm² solid or flexibleRemovable screw terminal block, 0.25...2.5 mm² flexible with ferrule single conductorRemovable screw terminal block, 0.2...1.5 mm² solid or flexible twin conductorRemovable screw terminal block, 2 x 0.25...1 mm² flexible with ferrule without cable end, with bezelRemovable screw terminal block, 2 x 0.5...1.5 mm² flexible with ferrule with cable end, with bezel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e[Us] rated supply voltage:\u003c\/th\u003e\n\u003ctd\u003e 48...240 V AC - 15...10 %48...240 V DC - 20...20 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"section-description\"\u003e\u003cdiv\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eSynchronisation time between inputs:\u003c\/th\u003e\n\u003ctd\u003e Unlimited\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of start:\u003c\/th\u003e\n\u003ctd\u003e Automatic\/manual\/monitored\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower consumption in W:\u003c\/th\u003e\n\u003ctd\u003e 2.0 W 48...240 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower consumption in VA:\u003c\/th\u003e\n\u003ctd\u003e 6.0 VA 48...240 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput protection type:\u003c\/th\u003e\n\u003ctd\u003e Internal, electronic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAuxiliary contact composition:\u003c\/th\u003e\n\u003ctd\u003e 4 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of inputs:\u003c\/th\u003e\n\u003ctd\u003e 0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput compatibility:\u003c\/th\u003e\n\u003ctd\u003e Normally closed circuit conforming to ISO 14119XC limit switch conforming to ISO 14119Mechanical contact conforming to ISO 14119Normally closed circuit conforming to ISO 13850\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTerminal identifier:\u003c\/th\u003e\n\u003ctd\u003e Power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e[Ie] rated operational current:\u003c\/th\u003e\n\u003ctd\u003e 5 A AC-1 for normally open relay contact3 A AC-15 for normally open relay contact5 A DC-1 for normally open relay contact3 A DC-13 for normally open relay contact3 A AC-1 for normally closed relay contact1 A AC-15 for normally closed relay contact3 A DC-1 for normally closed relay contact1 A DC-13 for normally closed relay contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of outputs:\u003c\/th\u003e\n\u003ctd\u003e 0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e[Ith] conventional free air thermal current:\u003c\/th\u003e\n\u003ctd\u003e 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAssociated fuse rating:\u003c\/th\u003e\n\u003ctd\u003e 10 A gG for NO relay output circuit conforming to IEC 60947-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMinimum output current:\u003c\/th\u003e\n\u003ctd\u003e 10 mA for relay output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMinimum output voltage:\u003c\/th\u003e\n\u003ctd\u003e 5 V for relay output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eResponse time:\u003c\/th\u003e\n\u003ctd\u003e 60 ms at 48...240 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e[Ui] rated insulation voltage:\u003c\/th\u003e\n\u003ctd\u003e 300 V (pollution degree 2) conforming to EN\/IEC 60947-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e[Uimp] rated impulse withstand voltage:\u003c\/th\u003e\n\u003ctd\u003e 4 kV overvoltage category II conforming to EN\/IEC 60947-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLocal signalling:\u003c\/th\u003e\n\u003ctd\u003e LED green with power marking for power ONLED red with error marking for errorLED yellow with state marking for statusLED yellow with start1 marking for start inputLED yellow with start2 marking for start input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting support:\u003c\/th\u003e\n\u003ctd\u003e 35 mm symmetrical DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDepth:\u003c\/th\u003e\n\u003ctd\u003e 120 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight:\u003c\/th\u003e\n\u003ctd\u003e 100 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth:\u003c\/th\u003e\n\u003ctd\u003e 22.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNet weight:\u003c\/th\u003e\n\u003ctd\u003e 0.200 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\n\u003cdiv class=\"section-additional\"\u003e\u003cdiv\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient air temperature for operation:\u003c\/th\u003e\n\u003ctd\u003e -25...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandards:\u003c\/th\u003e\n\u003ctd\u003e IEC 60947-5-1IEC 61508-1 functional safety standardIEC 61508-2 functional safety standardIEC 61508-3 functional safety standardIEC 61508-4 functional safety standardIEC 61508-5 functional safety standardIEC 61508-6 functional safety standardIEC 61508-7 functional safety standardISO 13849-1 functional safety standardIEC 62061 functional safety standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct certifications:\u003c\/th\u003e\n\u003ctd\u003e TÜVcULus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIP degree of protection:\u003c\/th\u003e\n\u003ctd\u003e IP20 (terminals) conforming to EN\/IEC 60529IP40 (housing) conforming to EN\/IEC 60529IP54 (mounting area) conforming to EN\/IEC 60529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative humidity:\u003c\/th\u003e\n\u003ctd\u003e 5...95 % non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSustainable offer status:\u003c\/th\u003e\n\u003ctd\u003e Green Premium productREACh Regulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnit Type of Package 1:\u003c\/th\u003e\n\u003ctd\u003e PCENumber of Units in Package 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\n\u003cdiv class=\"table-wrapper\" id=\"product-attributes\"\u003e\u003ctable class=\"additional-attributes w-full text-xs lg:text-xl\"\u003e \u003ctr class=\"\"\u003e\n\u003cth class=\"col label w-5\/12 lg:w-1\/4 py-1.5 text-left text-gray-600 font-normal align-top product-attribute-label\" scope=\"row\"\u003eCode EAN:\u003c\/th\u003e\n\u003ctd class=\"col data w-7\/12 lg:w-3\/4 py-1.5 pl-2 lg:pl-20 text-left product-attribute-value\" data-th=\"Code EAN\"\u003e3606482034020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":44209277009974,"sku":"XPSBAC34AP","price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0698\/4712\/1974\/files\/XPSBAC34AP.png?v=1760119034","url":"https:\/\/www.tehonet.fi\/products\/schneider-electric-estop-or-guard-harmony-xps-connected-to-supply-terminals-48-240-v-ac-dc-no-inputs-screw-xpsbac34ap","provider":"TEHONET Power Electronics, Electrical \u0026 Automation equipment and components","version":"1.0","type":"link"}