{"product_id":"schneider-electric-harmony-k1-k2-cam-changeover-switch-2-poles-45-12-a-screw-mounting-k1d002ulh","title":"Harmony K1, K2, Cam changeover switch 2 poles, 45°, 12 A, screw mounting - K1D002ULH","description":"\u003cdiv class=\"section-product-attributes\"\u003e \u003cdiv\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eRange of product:\u003c\/th\u003e\n\u003ctd\u003e Harmony K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct or component type:\u003c\/th\u003e\n\u003ctd\u003e Complete cam switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eComponent name:\u003c\/th\u003e\n\u003ctd\u003e K1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e[Ith] conventional free air thermal current:\u003c\/th\u003e\n\u003ctd\u003e 12 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct mounting:\u003c\/th\u003e\n\u003ctd\u003e Front mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFixing mode:\u003c\/th\u003e\n\u003ctd\u003e Multifixing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCam switch head type:\u003c\/th\u003e\n\u003ctd\u003e With front plate 45 x 45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of operator:\u003c\/th\u003e\n\u003ctd\u003e Black handle, length = 35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRotary handle padlocking:\u003c\/th\u003e\n\u003ctd\u003e Without\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePresentation of legend:\u003c\/th\u003e\n\u003ctd\u003e With metallic legend, 2 - 0 - 1 black marking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCam switch function:\u003c\/th\u003e\n\u003ctd\u003e Changeover switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReturn:\u003c\/th\u003e\n\u003ctd\u003e Without\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOff position:\u003c\/th\u003e\n\u003ctd\u003e With Off position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePoles description:\u003c\/th\u003e\n\u003ctd\u003e 2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching positions:\u003c\/th\u003e\n\u003ctd\u003e Left: 0° - 315°Right: 0° - 45°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIP degree of protection:\u003c\/th\u003e\n\u003ctd\u003e IP40 conforming to IEC 529IP40 conforming to NF C 20-010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"section-description\"\u003e\u003cdiv\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching angle:\u003c\/th\u003e\n\u003ctd\u003e 45 °\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e[Ui] rated insulation voltage:\u003c\/th\u003e\n\u003ctd\u003e 690 V (pollution degree 3) conforming to IEC 60947-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e[Ithe] conventional enclosed thermal current:\u003c\/th\u003e\n\u003ctd\u003e 10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated operational power in W:\u003c\/th\u003e\n\u003ctd\u003e 10500 W AC-21, 500...660 V 3 phases conforming to IEC 947-31100 W AC-3, 230 V 3 phases conforming to IEC 947-31500 W AC-23A, 230 V 3 phases conforming to IEC 947-31500 W AC-3, 400 V 1 phase conforming to IEC 947-31500 W AC-3, 400 V 3 phases conforming to IEC 947-31500 W AC-3, 500 V 3 phases conforming to IEC 947-31500 W AC-3, 690 V 3 phases conforming to IEC 947-32200 W AC-23A, 400 V 3 phases conforming to IEC 947-32200 W AC-23A, 500 V 3 phases conforming to IEC 947-32200 W AC-23A, 690 V 3 phases conforming to IEC 947-34800 W AC-21, 230 V 3 phases conforming to IEC 947-3600 W AC-3, 230 V 1 phase conforming to IEC 947-38300 W AC-21, 400 V 3 phases conforming to IEC 947-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e[Ie] rated operational current AC:\u003c\/th\u003e\n\u003ctd\u003e 1.8 A at 690 V AC-3 3 phases conforming to IEC 947-32.8 A at 500 V AC-3 3 phases conforming to IEC 947-32.8 A at 690 V AC-23A 3 phases conforming to IEC 947-33.3 A at 400 V AC-3 3 phases conforming to IEC 947-33.8 A at 500 V AC-23A 3 phases conforming to IEC 947-34.6 A at 230 V AC-3 3 phases conforming to IEC 947-34.8 A at 400 V AC-23A 3 phases conforming to IEC 947-35.6 A at 230 V AC-23A 3 phases conforming to IEC 947-31 A at 500 V AC-15 conforming to IEC 947-5-12 A at 400 V AC-15 conforming to IEC 947-5-13 A at 230 V AC-15 conforming to IEC 947-5-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical durability:\u003c\/th\u003e\n\u003ctd\u003e 1000000 cycles AC-151000000 cycles AC-21500000 cycles AC-23500000 cycles AC-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum operating rate:\u003c\/th\u003e\n\u003ctd\u003e 2.5 cyc\/mn AC-212.5 cyc\/mn AC-232.5 cyc\/mn AC-38.333 cyc\/mn AC-15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShort-circuit current:\u003c\/th\u003e\n\u003ctd\u003e 10000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShort-circuit protection:\u003c\/th\u003e\n\u003ctd\u003e 16 A cartridge fuse, type gG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e[Uimp] rated impulse withstand voltage:\u003c\/th\u003e\n\u003ctd\u003e 4 kV in isolating function6 kV conforming to IEC 947-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eContact operation:\u003c\/th\u003e\n\u003ctd\u003e Slow-break\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePositive opening:\u003c\/th\u003e\n\u003ctd\u003e With\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical connection:\u003c\/th\u003e\n\u003ctd\u003e Captive screw clamp terminals flexible, clamping capacity: 2 x 1.5 mm²Captive screw clamp terminals solid, clamping capacity: 1 x 2.5 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMechanical durability:\u003c\/th\u003e\n\u003ctd\u003e 1000000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCAD overall width:\u003c\/th\u003e\n\u003ctd\u003e 45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCAD overall height:\u003c\/th\u003e\n\u003ctd\u003e 45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCAD overall depth:\u003c\/th\u003e\n\u003ctd\u003e 87 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNet weight:\u003c\/th\u003e\n\u003ctd\u003e 0.14 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCompatibility code:\u003c\/th\u003e\n\u003ctd\u003e K1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\n\u003cdiv class=\"section-additional\"\u003e\u003cdiv\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eStandards:\u003c\/th\u003e\n\u003ctd\u003e EN 60947-3 for power circuitEN 60947-5-1 for control circuitIEC 60947-3 for power circuitIEC 60947-5-1 for control circuitCENELEC EN 50013\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct certifications:\u003c\/th\u003e\n\u003ctd\u003e CSA 240 V 3 hp 3 phases 2 pole(s)UL 240 V 0.33 hp 1 phase 2 pole(s)CSA 240 V 1 hp 1 phaseUL 240 V 1 hp 3 phases\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtective treatment:\u003c\/th\u003e\n\u003ctd\u003e TC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient air temperature for operation:\u003c\/th\u003e\n\u003ctd\u003e -25...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient air temperature for storage:\u003c\/th\u003e\n\u003ctd\u003e -40...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShock resistance:\u003c\/th\u003e\n\u003ctd\u003e 30 gn conforming to IEC 68-2-27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVibration resistance:\u003c\/th\u003e\n\u003ctd\u003e 5 gn conforming to IEC 68-2-6 (f = 10...150 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical shock protection class:\u003c\/th\u003e\n\u003ctd\u003e Class II conforming to IEC 536Class II conforming to NF C 20-030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSustainable offer status:\u003c\/th\u003e\n\u003ctd\u003e Green Premium productREACh Regulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnit Type of Package 1:\u003c\/th\u003e\n\u003ctd\u003e PCENumber of Units in Package 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\n\u003cdiv class=\"table-wrapper\" id=\"product-attributes\"\u003e\u003ctable class=\"additional-attributes w-full text-xs lg:text-xl\"\u003e \u003ctr class=\"\"\u003e\n\u003cth class=\"col label w-5\/12 lg:w-1\/4 py-1.5 text-left text-gray-600 font-normal align-top product-attribute-label\" scope=\"row\"\u003eCode EAN:\u003c\/th\u003e\n\u003ctd class=\"col data w-7\/12 lg:w-3\/4 py-1.5 pl-2 lg:pl-20 text-left product-attribute-value\" data-th=\"Code EAN\"\u003e3389110978544\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":44209295130678,"sku":"K1D002ULH","price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0698\/4712\/1974\/files\/K1D002ULH.png?v=1760119264","url":"https:\/\/www.tehonet.fi\/products\/schneider-electric-harmony-k1-k2-cam-changeover-switch-2-poles-45-12-a-screw-mounting-k1d002ulh","provider":"TEHONET Power Electronics, Electrical \u0026 Automation equipment and components","version":"1.0","type":"link"}