{"product_id":"schneider-electric-modular-multifunction-3-phase-supply-control-relay-5-a-1-co-208-480-v-ac-rm17tu00","title":"Modular multifunction 3-phase supply control relay, 5 A, 1 CO, 208...480 V AC - RM17TU00","description":"\u003cdiv class=\"section-product-attributes\"\u003e \u003cdiv\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eRange of product:\u003c\/th\u003e\n\u003ctd\u003e Harmony Control Relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct or component type:\u003c\/th\u003e\n\u003ctd\u003e 3-phase control relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelay type:\u003c\/th\u003e\n\u003ctd\u003e Multifunction control relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct specific application:\u003c\/th\u003e\n\u003ctd\u003e For 3-phase supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelay name:\u003c\/th\u003e\n\u003ctd\u003e RM17TU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelay monitored parameters:\u003c\/th\u003e\n\u003ctd\u003e Undervoltage detectionPhase sequencePhase failure detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTime delay type:\u003c\/th\u003e\n\u003ctd\u003e Adjustable 0.1...10 s, +\/- 10 % of the full scale value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching capacity in VA:\u003c\/th\u003e\n\u003ctd\u003e 1250 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMeasurement range:\u003c\/th\u003e\n\u003ctd\u003e 208...480 V voltage AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eContacts type and composition:\u003c\/th\u003e\n\u003ctd\u003e 1 C\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnections - terminals:\u003c\/th\u003e\n\u003ctd\u003e Screw connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e[Uc] control circuit voltage:\u003c\/th\u003e\n\u003ctd\u003e 208...480 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e[In] rated current:\u003c\/th\u003e\n\u003ctd\u003e 5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"section-description\"\u003e\u003cdiv\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eReset time:\u003c\/th\u003e\n\u003ctd\u003e 1500 ms time delay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum switching voltage:\u003c\/th\u003e\n\u003ctd\u003e 250 V AC250 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMinimum switching current:\u003c\/th\u003e\n\u003ctd\u003e 10 mA at 5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum switching current:\u003c\/th\u003e\n\u003ctd\u003e 5 A AC5 A DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupply voltage limits:\u003c\/th\u003e\n\u003ctd\u003e 183...528 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eControl circuit voltage limits:\u003c\/th\u003e\n\u003ctd\u003e - 12 % + 10 % Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower consumption in VA:\u003c\/th\u003e\n\u003ctd\u003e 0...22 VA at 400 V AC 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eControl circuit frequency:\u003c\/th\u003e\n\u003ctd\u003e 50...60 Hz +\/- 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput contacts:\u003c\/th\u003e\n\u003ctd\u003e 1 C\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal output current:\u003c\/th\u003e\n\u003ctd\u003e 5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMeasurement voltage limits:\u003c\/th\u003e\n\u003ctd\u003e 183...528 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHysteresis:\u003c\/th\u003e\n\u003ctd\u003e 2 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRun-up delay at power-up:\u003c\/th\u003e\n\u003ctd\u003e 650 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum measuring cycle:\u003c\/th\u003e\n\u003ctd\u003e 150 ms measurement cycle as true rms value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eThreshold adjustment voltage:\u003c\/th\u003e\n\u003ctd\u003e -2...-12 % in the range 208 V AC-2...-17 % in the range 220 V AC2...20 % of Un selected+2...+17 % in the range 480 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage range:\u003c\/th\u003e\n\u003ctd\u003e 208...480 V phase to phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAdjustment of asymmetry threshold:\u003c\/th\u003e\n\u003ctd\u003e 5...15 % of Un selected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRepeat accuracy:\u003c\/th\u003e\n\u003ctd\u003e 0.5 % for input and measurement circuit3 % for time delay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMeasurement error:\u003c\/th\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePhase failure sensitivity:\u003c\/th\u003e\n\u003ctd\u003e 0.7 Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eResponse time:\u003c\/th\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMarking:\u003c\/th\u003e\n\u003ctd\u003e CE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOvervoltage category:\u003c\/th\u003e\n\u003ctd\u003e III conforming to IEC 60664-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsulation resistance:\u003c\/th\u003e\n\u003ctd\u003e \u0026gt; 500 MOhm at 500 V DC conforming to IEC 60255-5\u0026gt; 500 MOhm at 500 V DC conforming to IEC 60664-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e[Ui] rated insulation voltage:\u003c\/th\u003e\n\u003ctd\u003e 400 V conforming to IEC 60664-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupply frequency:\u003c\/th\u003e\n\u003ctd\u003e 50\/60 Hz +\/- 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating position:\u003c\/th\u003e\n\u003ctd\u003e Any position without derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnections - terminals:\u003c\/th\u003e\n\u003ctd\u003e Screw terminals, 1 x 0.5...1 x 4 mm² (AWG 20...AWG 11) solid without cable endScrew terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable endScrew terminals, 1 x 0.2...1 x 2.5 mm² (AWG 24...AWG 12) flexible with cable endScrew terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) flexible with cable end\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTightening torque:\u003c\/th\u003e\n\u003ctd\u003e 0.6...1 N.m conforming to IEC 60947-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHousing material:\u003c\/th\u003e\n\u003ctd\u003e Self-extinguishing plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLocal signalling:\u003c\/th\u003e\n\u003ctd\u003e LED (green) for power ONLED (yellow) for relay ON\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting support:\u003c\/th\u003e\n\u003ctd\u003e 35 mm symmetrical DIN rail conforming to EN\/IEC 60715\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical durability:\u003c\/th\u003e\n\u003ctd\u003e 100000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMechanical durability:\u003c\/th\u003e\n\u003ctd\u003e 30000000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating rate:\u003c\/th\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUtilisation category:\u003c\/th\u003e\n\u003ctd\u003e AC-12 conforming to IEC 60947-5-1AC-13 conforming to IEC 60947-5-1AC-14 conforming to IEC 60947-5-1AC-15 conforming to IEC 60947-5-1DC-12 conforming to IEC 60947-5-1DC-13 conforming to IEC 60947-5-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety reliability data:\u003c\/th\u003e\n\u003ctd\u003e MTTFd = 502.2 yearsB10d = 470000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth:\u003c\/th\u003e\n\u003ctd\u003e 17.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight:\u003c\/th\u003e\n\u003ctd\u003e 0.13 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFunctionality:\u003c\/th\u003e\n\u003ctd\u003e Undervoltage detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCompatibility code:\u003c\/th\u003e\n\u003ctd\u003e RM17\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\n\u003cdiv class=\"section-additional\"\u003e\u003cdiv\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eElectromagnetic compatibility:\u003c\/th\u003e\n\u003ctd\u003e Emission standard for industrial environments conforming to EN\/IEC 61000-6-4Emission standard for residential, commercial and light-industrial environments conforming to EN\/IEC 61000-6-3Immunity for industrial environments conforming to EN\/IEC 61000-6-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandards:\u003c\/th\u003e\n\u003ctd\u003e EN\/IEC 60255-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct certifications:\u003c\/th\u003e\n\u003ctd\u003e GLGOSTULC-TickCSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDirectives:\u003c\/th\u003e\n\u003ctd\u003e 73\/23\/EEC - low voltage directive89\/336\/EEC - electromagnetic compatibility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient air temperature for storage:\u003c\/th\u003e\n\u003ctd\u003e -40...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient air temperature for operation:\u003c\/th\u003e\n\u003ctd\u003e -20...50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative humidity:\u003c\/th\u003e\n\u003ctd\u003e 95 % at 55 °C conforming to IEC 60068-2-30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVibration resistance:\u003c\/th\u003e\n\u003ctd\u003e 0.35 mm (f= 5...57.6 Hz) conforming to IEC 60068-2-61 gn (f= 57.6...150 Hz) conforming to IEC 60255-21-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShock resistance:\u003c\/th\u003e\n\u003ctd\u003e 15 gn for 11 ms conforming to IEC 60255-21-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIP degree of protection:\u003c\/th\u003e\n\u003ctd\u003e IP20 (terminals) conforming to IEC 60529IP30 (casing) conforming to IEC 60529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePollution degree:\u003c\/th\u003e\n\u003ctd\u003e 3 conforming to IEC 60664-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDielectric test voltage:\u003c\/th\u003e\n\u003ctd\u003e 2 kV, 1 min AC 50 Hz conforming to IEC 60255-52 kV, 1 min AC 50 Hz conforming to IEC 60664-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNon-dissipating shock wave:\u003c\/th\u003e\n\u003ctd\u003e 4 kV conforming to IEC 60255-54 kV conforming to IEC 60664-14 kV conforming to IEC 61000-4-5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSustainable offer status:\u003c\/th\u003e\n\u003ctd\u003e Green Premium productREACh Regulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\n\u003cdiv class=\"table-wrapper\" id=\"product-attributes\"\u003e\u003ctable class=\"additional-attributes w-full text-xs lg:text-xl\"\u003e \u003ctr class=\"\"\u003e\n\u003cth class=\"col label w-5\/12 lg:w-1\/4 py-1.5 text-left text-gray-600 font-normal align-top product-attribute-label\" scope=\"row\"\u003eCode EAN:\u003c\/th\u003e\n\u003ctd class=\"col data w-7\/12 lg:w-3\/4 py-1.5 pl-2 lg:pl-20 text-left product-attribute-value\" data-th=\"Code EAN\"\u003e3389119405096\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":44209401069622,"sku":"RM17TU00","price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0698\/4712\/1974\/files\/RM17TU00.jpg?v=1760121204","url":"https:\/\/www.tehonet.fi\/products\/schneider-electric-modular-multifunction-3-phase-supply-control-relay-5-a-1-co-208-480-v-ac-rm17tu00","provider":"TEHONET Power Electronics, Electrical \u0026 Automation equipment and components","version":"1.0","type":"link"}