{"product_id":"schneider-electric-motor-controller-ltmr-tesys-t-24-v-dc-8-a-for-canopen-ltmr08cbd","title":"motor controller LTMR TeSys T - 24 V DC 8 A for CANopen - LTMR08CBD","description":"\u003cdiv class=\"section-product-attributes\"\u003e \u003cdiv\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eRange:\u003c\/th\u003e\n\u003ctd\u003e TeSys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct name:\u003c\/th\u003e\n\u003ctd\u003e TeSys T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDevice short name:\u003c\/th\u003e\n\u003ctd\u003e LTMR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct or component type:\u003c\/th\u003e\n\u003ctd\u003e Motor controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDevice application:\u003c\/th\u003e\n\u003ctd\u003e Equipment monitoring and control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMeasurement current:\u003c\/th\u003e\n\u003ctd\u003e 0.4...8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e[Us] rated supply voltage:\u003c\/th\u003e\n\u003ctd\u003e 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCurrent consumption:\u003c\/th\u003e\n\u003ctd\u003e 56...127 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupply voltage limits:\u003c\/th\u003e\n\u003ctd\u003e 20.4...26.24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication port protocol:\u003c\/th\u003e\n\u003ctd\u003e CANopen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBus type:\u003c\/th\u003e\n\u003ctd\u003e CANopen ISO 1198 interface, addressing 1...127, transmission rate 10...1000 kbit\/s, SUB-D 9 with 4 twisted shielded pairs cableCANopen ISO 1198 interface, addressing 1...127, transmission rate 10...1000 kbit\/s, terminal block with 4 twisted shielded pairs cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"section-description\"\u003e\u003cdiv\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003e[Ui] rated insulation voltage:\u003c\/th\u003e\n\u003ctd\u003e 690 V conforming to EN\/IEC 60947-1690 V conforming to CSA C22.2 No 14690 V conforming to UL 508\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e[Uimp] rated impulse withstand voltage:\u003c\/th\u003e\n\u003ctd\u003e 6 kV current or voltage measurement circuit conforming to EN\/IEC 60947-4-10.8 kV communication circuit conforming to EN\/IEC 60947-4-10.8 kV supply, inputs and outputs conforming to EN\/IEC 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShort-circuit withstand:\u003c\/th\u003e\n\u003ctd\u003e 100 kA conforming to EN\/IEC 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAssociated fuse rating:\u003c\/th\u003e\n\u003ctd\u003e 4 A gG for output0.5 A gG for control circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection type:\u003c\/th\u003e\n\u003ctd\u003e Overload (long time)Phase failureLoad fluctuationPhase imbalanceReverse polarity protectionThermal protectionThermal overload protectionEarth-leakage protectionPower factor variationOverloadLocked rotor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNetwork and machine diagnosis type:\u003c\/th\u003e\n\u003ctd\u003e Trip context informationRemaining operating time before overload trippingStarting current and timeEvent recordingMotor control command recordingRunning hours counter\/operating timeWaiting time after overload trippingTrip history informationPhase fault and earth fault trip countersFault recording\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLogic input number:\u003c\/th\u003e\n\u003ctd\u003e 6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput current:\u003c\/th\u003e\n\u003ctd\u003e 7 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCurrent state 0 guaranteed:\u003c\/th\u003e\n\u003ctd\u003e Logic input: \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCurrent state 1 guaranteed:\u003c\/th\u003e\n\u003ctd\u003e Logic input: \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum operating frequency:\u003c\/th\u003e\n\u003ctd\u003e 2 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLoad current:\u003c\/th\u003e\n\u003ctd\u003e 5 A at 250 V AC for logic output5 A at 30 V DC for logic output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePermissible power:\u003c\/th\u003e\n\u003ctd\u003e 480 VA (AC-15), Ie = 2 A, 500000 cycles (output)30 W (DC-13), Ie = 1.25 A, 500000 cycles (output)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum operating rate:\u003c\/th\u003e\n\u003ctd\u003e 1800 cyc\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eContacts type and composition:\u003c\/th\u003e\n\u003ctd\u003e 1 NO + 1 NC fault signal3 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMetering type:\u003c\/th\u003e\n\u003ctd\u003e Average current IavgPhase current I1, I2, I3 RMSTemperatureEarth-fault currentImbalance current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMeasurement accuracy:\u003c\/th\u003e\n\u003ctd\u003e 5...15 % earth fault current internal measurement1 % voltage (100...830 V)3 % power factor5 % earth fault current external measurement+\/- 30 min\/year internal clock0,02 temperature1 % current5 % active and reactive power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOvervoltage category:\u003c\/th\u003e\n\u003ctd\u003e III\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnection pitch:\u003c\/th\u003e\n\u003ctd\u003e 5.08 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnections - terminals:\u003c\/th\u003e\n\u003ctd\u003e Control circuit: connector 1 cable(s) 0.25...2.5 mm² (AWG 24...AWG 14) flexible with cable endControl circuit: connector 1 cable(s) 0.2...2.5 mm² (AWG 24...AWG 14) flexible without cable endControl circuit: connector 1 cable(s) 0.25...2.5 mm² (AWG 24...AWG 14) flexible without cable endControl circuit: connector 1 cable(s) 0.2...2.5 mm² (AWG 24...AWG 14) solid without cable endControl circuit: connector 2 cable(s) 0.2...1 mm² (AWG 24...AWG 14) flexible with cable endControl circuit: connector 2 cable(s) 0.2...1.5 mm² (AWG 24...AWG 14) flexible without cable endControl circuit: connector 2 cable(s) 0.5...1.5 mm² (AWG 24...AWG 14) flexible without cable endControl circuit: connector 2 cable(s) 0.2...1 mm² (AWG 24...AWG 14) solid without cable end\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTightening torque:\u003c\/th\u003e\n\u003ctd\u003e Control circuit: 0.5...0.6 N.m flat screwdriver 3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePollution degree:\u003c\/th\u003e\n\u003ctd\u003e 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectromagnetic compatibility:\u003c\/th\u003e\n\u003ctd\u003e Electrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN\/IEC 61000-4-2Radiated RF fields, 3, 10 V\/m, conforming to EN\/IEC 61000-4-3Fast transients immunity test (other circuits), level 3, 2 kV, conforming to EN\/IEC 61000-4-4Fast transients immunity test (on supply and relay outputs), level 4, 4 kV, conforming to EN\/IEC 61000-4-4Voltage dips and interruptions immunity test, 70 %, 500 ms, conforming to EN\/IEC 61000-4-11Conducted RF disturbances, 10 V, conforming to EN\/IEC 61000-4-6Temperature sensor: surges (serial mode), 0.5 kV, conforming to EN\/IEC 61000-4-5Temperature sensor: surges (common mode), 1 kV, conforming to EN\/IEC 61000-4-5Control circuit: surges (serial mode), 1 kV, conforming to EN\/IEC 61000-4-5Control circuit: surges (common mode), 1 kV, conforming to EN\/IEC 61000-4-5Communication: surges (common mode), 2 kV, conforming to EN\/IEC 61000-4-5Relay outputs and supply: surges (serial mode), 2 kV, conforming to EN\/IEC 61000-4-5Relay outputs and supply: surges (common mode), 4 kV, conforming to EN\/IEC 61000-4-5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth:\u003c\/th\u003e\n\u003ctd\u003e 91 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight:\u003c\/th\u003e\n\u003ctd\u003e 61 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDepth:\u003c\/th\u003e\n\u003ctd\u003e 122.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight:\u003c\/th\u003e\n\u003ctd\u003e 0.53 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeb services:\u003c\/th\u003e\n\u003ctd\u003e Web server\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCompatibility code:\u003c\/th\u003e\n\u003ctd\u003e LTMR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\n\u003cdiv class=\"section-additional\"\u003e\u003cdiv\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eStandards:\u003c\/th\u003e\n\u003ctd\u003e EN 60947-4-1CSA C22.2 No 14IEC 60947-4-1UL 508IACS E10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct certifications:\u003c\/th\u003e\n\u003ctd\u003e ATEXC-TickEACLROS (Lloyds register of shipping)NOMBVRINAKERIABSULCSADNVRMRoSGLCCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtective treatment:\u003c\/th\u003e\n\u003ctd\u003e 12 x 24 hour cycles conforming to EN\/IEC 60068-2-3048 h conforming to EN\/IEC 60070-2-11TH conforming to EN\/IEC 60068\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFire resistance:\u003c\/th\u003e\n\u003ctd\u003e 650 °C conforming to EN\/IEC 60695-2-12960 °C conforming to UL 94\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient air temperature for operation:\u003c\/th\u003e\n\u003ctd\u003e -20...60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient air temperature for storage:\u003c\/th\u003e\n\u003ctd\u003e -40...80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating altitude:\u003c\/th\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMechanical robustness:\u003c\/th\u003e\n\u003ctd\u003e Vibrations mounted on symmetrical rail: 1 Gn, 5...300 Hz conforming to EN\/IEC 60068-2-6Vibrations plate mounted: 4 Gn, 5...300 Hz conforming to EN\/IEC 60068-2-6Shocks half sine wave acceleration: 15 Gn for 11 ms conforming to EN\/IEC 60068-2-27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIP degree of protection:\u003c\/th\u003e\n\u003ctd\u003e IP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSustainable offer status:\u003c\/th\u003e\n\u003ctd\u003e Green Premium productREACh Regulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\n\u003cdiv class=\"table-wrapper\" id=\"product-attributes\"\u003e\u003ctable class=\"additional-attributes w-full text-xs lg:text-xl\"\u003e \u003ctr class=\"\"\u003e\n\u003cth class=\"col label w-5\/12 lg:w-1\/4 py-1.5 text-left text-gray-600 font-normal align-top product-attribute-label\" scope=\"row\"\u003eCode EAN:\u003c\/th\u003e\n\u003ctd class=\"col data w-7\/12 lg:w-3\/4 py-1.5 pl-2 lg:pl-20 text-left product-attribute-value\" data-th=\"Code EAN\"\u003e3389119404686\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":44209411424310,"sku":"LTMR08CBD","price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0698\/4712\/1974\/files\/LTMR08CBD.png?v=1760121397","url":"https:\/\/www.tehonet.fi\/products\/schneider-electric-motor-controller-ltmr-tesys-t-24-v-dc-8-a-for-canopen-ltmr08cbd","provider":"TEHONET Power Electronics, Electrical \u0026 Automation equipment and components","version":"1.0","type":"link"}