{"product_id":"schneider-electric-preventa-module-cat-4-features-2-xpsuaf-enabling-movement-24vac-dc-screw-xpsus12ap","title":"Preventa module Cat.4 features 2*XPSUAF + enabling movement 24vac\/dc screw - XPSUS12AP","description":"\u003cdiv class=\"section-product-attributes\"\u003e \u003cdiv\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eRange of product:\u003c\/th\u003e\n\u003ctd\u003e Harmony Safety Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct or component type:\u003c\/th\u003e\n\u003ctd\u003e Safety module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety module name:\u003c\/th\u003e\n\u003ctd\u003e XPSUS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety module application:\u003c\/th\u003e\n\u003ctd\u003e For electrical monitoring of two-hand control stationsMonitoring antivalent contactsFor emergency stop, guard and light curtain monitoringFor enabling switch monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFunction of module:\u003c\/th\u003e\n\u003ctd\u003e Emergency stop button with 2 NC contactsGuard monitoring with 1 or 2 limit switchesMonitoring 2 PNP sensorsMagnetic switch monitoringLight curtain monitoringRFID switchMonitoring of electro-sensitive protection equipment (ESPE)Enabling switch monitoringProximity sensor monitoringMonitoring two-hand control station\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety level:\u003c\/th\u003e\n\u003ctd\u003e Can reach PL e\/category 4 conforming to ISO 13849-1Can reach SILCL 3 conforming to IEC 62061Can reach SIL 3 conforming to IEC 61508\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety reliability data:\u003c\/th\u003e\n\u003ctd\u003e MTTFd \u0026gt; 30 years conforming to ISO 13849-1Dcavg \u0026gt;= 99 % conforming to ISO 13849-1PFHd = 1.13E-09 conforming to ISO 13849-1HFT = 1 conforming to IEC 62061PFHd = 1.13E-09 conforming to IEC 62061SFF \u0026gt; 99% conforming to IEC 62061HFT = 1 conforming to IEC 61508-1PFHd = 1.13E-09 conforming to IEC 61508-1SFF \u0026gt; 99% conforming to IEC 61508-1Type = B conforming to IEC 61508-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical circuit type:\u003c\/th\u003e\n\u003ctd\u003e NC pairPNP pairAntivalent pairOSSD pair\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnections - terminals:\u003c\/th\u003e\n\u003ctd\u003e Removable screw terminal block, 0.2...2.5 mm² solid or flexibleRemovable screw terminal block, 0.25...2.5 mm² flexible with ferrule single conductorRemovable screw terminal block, 0.2...1.5 mm² solid or flexible twin conductorRemovable screw terminal block, 2 x 0.25...1 mm² flexible with ferrule without cable end, with bezelRemovable screw terminal block, 2 x 0.5...1.5 mm² flexible with ferrule with cable end, with bezel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e[Us] rated supply voltage:\u003c\/th\u003e\n\u003ctd\u003e 24 V AC - 15...10 %24 V DC - 20...20 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"section-description\"\u003e\u003cdiv\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eSynchronisation time between inputs:\u003c\/th\u003e\n\u003ctd\u003e 0.5 s2 s4 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of start:\u003c\/th\u003e\n\u003ctd\u003e Automatic\/manual\/monitored\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower consumption in W:\u003c\/th\u003e\n\u003ctd\u003e 2 W 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower consumption in VA:\u003c\/th\u003e\n\u003ctd\u003e 5.0 VA 24 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput protection type:\u003c\/th\u003e\n\u003ctd\u003e Internal, electronic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAuxiliary contact composition:\u003c\/th\u003e\n\u003ctd\u003e 2 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of inputs:\u003c\/th\u003e\n\u003ctd\u003e 2 safety input 24 V DC 5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum line resistance:\u003c\/th\u003e\n\u003ctd\u003e 500 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput compatibility:\u003c\/th\u003e\n\u003ctd\u003e Normally closed circuit conforming to ISO 14119XC limit switch conforming to ISO 14119Mechanical contact conforming to ISO 14119Normally closed circuit conforming to ISO 13850Antivalent pair conforming to ISO 14119OSSD pair conforming to IEC 61496-1-2Two-hand control conforming to EN 574\/ISO 13851-III ATwo-hand control conforming to EN 574\/ISO 13851-III C3-wire proximity sensors PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e[Ie] rated operational current:\u003c\/th\u003e\n\u003ctd\u003e 5 A AC-1 for normally open relay contact3 A AC-15 for normally open relay contact5 A DC-1 for normally open relay contact3 A DC-13 for normally open relay contact3 A AC-1 for normally closed relay contact1 A AC-15 for normally closed relay contact3 A DC-1 for normally closed relay contact1 A DC-13 for normally closed relay contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of outputs:\u003c\/th\u003e\n\u003ctd\u003e 3 on\/off configurable pulsed output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput\/output type:\u003c\/th\u003e\n\u003ctd\u003e Semiconductor pulsed diagnostic output 24 V DC, 20 mA Z1, not safety-related\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e[Ith] conventional free air thermal current:\u003c\/th\u003e\n\u003ctd\u003e 8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAssociated fuse rating:\u003c\/th\u003e\n\u003ctd\u003e 10 A gG for NO relay output circuit conforming to IEC 60947-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMinimum output current:\u003c\/th\u003e\n\u003ctd\u003e 10 mA for relay output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMinimum output voltage:\u003c\/th\u003e\n\u003ctd\u003e 12 V for relay output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum response time on input open:\u003c\/th\u003e\n\u003ctd\u003e 20 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e[Ui] rated insulation voltage:\u003c\/th\u003e\n\u003ctd\u003e 250 V (pollution degree 2) conforming to EN\/IEC 60947-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e[Uimp] rated impulse withstand voltage:\u003c\/th\u003e\n\u003ctd\u003e 4 kV overvoltage category II conforming to EN\/IEC 60947-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLocal signalling:\u003c\/th\u003e\n\u003ctd\u003e LED (green) for power ONLED (red) for errorLED (yellow) for safety output statusLED (yellow) for start inputLED (yellow) for safety input S12LED (yellow) for safety input S13LED (yellow) for safety input S22LED (yellow) for safety input S23\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting support:\u003c\/th\u003e\n\u003ctd\u003e 35 mm symmetrical DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDepth:\u003c\/th\u003e\n\u003ctd\u003e 120 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight:\u003c\/th\u003e\n\u003ctd\u003e 100 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth:\u003c\/th\u003e\n\u003ctd\u003e 22.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNet weight:\u003c\/th\u003e\n\u003ctd\u003e 0.200 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\n\u003cdiv class=\"section-additional\"\u003e\u003cdiv\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eStandards:\u003c\/th\u003e\n\u003ctd\u003e IEC 60947-5-1IEC 61508-1 functional safety standardIEC 61508-2 functional safety standardIEC 61508-3 functional safety standardIEC 61508-4 functional safety standardIEC 61508-5 functional safety standardIEC 61508-6 functional safety standardIEC 61508-7 functional safety standardISO 13849-1 functional safety standardIEC 62061 functional safety standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct certifications:\u003c\/th\u003e\n\u003ctd\u003e TÜVcULus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIP degree of protection:\u003c\/th\u003e\n\u003ctd\u003e IP20 (terminals) conforming to EN\/IEC 60529IP40 (housing) conforming to EN\/IEC 60529IP54 (mounting area) conforming to EN\/IEC 60529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient air temperature for storage:\u003c\/th\u003e\n\u003ctd\u003e -25...85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative humidity:\u003c\/th\u003e\n\u003ctd\u003e 5...95 % non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSustainable offer status:\u003c\/th\u003e\n\u003ctd\u003e Green Premium productREACh Regulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnit Type of Package 1:\u003c\/th\u003e\n\u003ctd\u003e PCENumber of Units in Package 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\n\u003cdiv class=\"table-wrapper\" id=\"product-attributes\"\u003e\u003ctable class=\"additional-attributes w-full text-xs lg:text-xl\"\u003e \u003ctr class=\"\"\u003e\n\u003cth class=\"col label w-5\/12 lg:w-1\/4 py-1.5 text-left text-gray-600 font-normal align-top product-attribute-label\" scope=\"row\"\u003eCode EAN:\u003c\/th\u003e\n\u003ctd class=\"col data w-7\/12 lg:w-3\/4 py-1.5 pl-2 lg:pl-20 text-left product-attribute-value\" data-th=\"Code EAN\"\u003e3606489601812\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":44209695260726,"sku":"XPSUS12AP","price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0698\/4712\/1974\/files\/XPSUS12AP.png?v=1760127229","url":"https:\/\/www.tehonet.fi\/products\/schneider-electric-preventa-module-cat-4-features-2-xpsuaf-enabling-movement-24vac-dc-screw-xpsus12ap","provider":"TEHONET Power Electronics, Electrical \u0026 Automation equipment and components","version":"1.0","type":"link"}