{"product_id":"schneider-electric-residual-current-protection-relay-vigirex-rh197m-30-ma-to-30-a-220-240-vac-50-60hz-alarm-50-or-100-din-rail-mounting-56517","title":"residual current protection relay, Vigirex RH197M, 30 mA to 30 A, 220\/240 VAC 50\/60Hz, alarm 50% or 100%, DIN rail mounting - 56517","description":"\u003cdiv class=\"section-product-attributes\"\u003e \u003cdiv\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eRange:\u003c\/th\u003e\n\u003ctd\u003e VigiPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDevice short name:\u003c\/th\u003e\n\u003ctd\u003e RH197M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct or component type:\u003c\/th\u003e\n\u003ctd\u003e Residual current protection relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelay application:\u003c\/th\u003e\n\u003ctd\u003e Protection relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting support:\u003c\/th\u003e\n\u003ctd\u003e DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEarth-leakage protection class:\u003c\/th\u003e\n\u003ctd\u003e Type A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of setting:\u003c\/th\u003e\n\u003ctd\u003e Selector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eResidual earth-leakage sensitity adjustment type:\u003c\/th\u003e\n\u003ctd\u003e Adjustable 19 settings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEarth leakage current:\u003c\/th\u003e\n\u003ctd\u003e 0.03...30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eResidual earth-leakage time delay adjustment type:\u003c\/th\u003e\n\u003ctd\u003e Instantaneous for 0.03 AAdjustable 7 settings 0...4.5 s for 0.03...30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAlarm threshold:\u003c\/th\u003e\n\u003ctd\u003e 100 %50 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRange compatibility:\u003c\/th\u003e\n\u003ctd\u003e  TOA earth leakage current sensor A earth leakage current sensor L earth leakage current sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e[Ithe] conventional enclosed thermal current:\u003c\/th\u003e\n\u003ctd\u003e 8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMinimum load:\u003c\/th\u003e\n\u003ctd\u003e 10 mA at 12 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e[Us] rated supply voltage:\u003c\/th\u003e\n\u003ctd\u003e 220...240 V AC 50\/60 Hz 70...110 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower consumption in VA:\u003c\/th\u003e\n\u003ctd\u003e 4 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNetwork rated voltage:\u003c\/th\u003e\n\u003ctd\u003e 1000 V - AC at 50\/60 Hz (maximum) 1000 V - AC at 400 Hz (maximum) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEarthing system:\u003c\/th\u003e\n\u003ctd\u003e TTTN-SIT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e[Uimp] rated impulse withstand voltage:\u003c\/th\u003e\n\u003ctd\u003e 8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReset:\u003c\/th\u003e\n\u003ctd\u003e Manual resetAutomatic reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"section-description\"\u003e\u003cdiv\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eTest function:\u003c\/th\u003e\n\u003ctd\u003e LocalRemote test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMonitoring:\u003c\/th\u003e\n\u003ctd\u003e Electronics (watchdog) Power supply (continuous) Relay\/sensor link (continuous) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSignal contacts composition:\u003c\/th\u003e\n\u003ctd\u003e 1 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of measurement:\u003c\/th\u003e\n\u003ctd\u003e Earth fault current internal measurement, range: 80...100 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRefresh time:\u003c\/th\u003e\n\u003ctd\u003e 0.5 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTamperproof of settings:\u003c\/th\u003e\n\u003ctd\u003e Protected by sealable cover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnections - terminals:\u003c\/th\u003e\n\u003ctd\u003e Auxiliary power supply: terminal block cable(s) 0.2...2.5 mm² flexible AWG 24...AWG 12Auxiliary power supply: terminal block cable(s) 0.2...2.5 mm² rigid AWG 24...AWG 12Auxiliary power supply: terminal block cable(s) 0.25...2.5 mm² flexible AWG 24...AWG 12Fault: terminal block cable(s) 0.2...2.5 mm² flexible AWG 24...AWG 12Fault: terminal block cable(s) 0.2...2.5 mm² rigid AWG 24...AWG 12Fault: terminal block cable(s) 0.25...2.5 mm² flexible AWG 24...AWG 12Relay test and fault reset: terminal block cable(s) 0.2...2.5 mm² flexible AWG 24...AWG 12Relay test and fault reset: terminal block cable(s) 0.2...2.5 mm² rigid AWG 24...AWG 12Relay test and fault reset: terminal block cable(s) 0.25...2.5 mm² flexible AWG 24...AWG 12Sensor: terminal block cable(s) 0.2...2.5 mm² flexible AWG 24...AWG 12Sensor: terminal block cable(s) 0.2...2.5 mm² rigid AWG 24...AWG 12Sensor: terminal block cable(s) 0.25...2.5 mm² flexible AWG 24...AWG 12Voltage presence: terminal block cable(s) 0.2...2.5 mm² flexible AWG 24...AWG 12Voltage presence: terminal block cable(s) 0.2...2.5 mm² rigid AWG 24...AWG 12Voltage presence: terminal block cable(s) 0.25...2.5 mm² flexible AWG 24...AWG 12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWire stripping length:\u003c\/th\u003e\n\u003ctd\u003e Auxiliary power supply: 7 mmFault: 7 mmRelay test and fault reset: 7 mmSensor: 7 mmVoltage presence: 7 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTightening torque:\u003c\/th\u003e\n\u003ctd\u003e Auxiliary power supply: 0.6 N.mFault: 0.6 N.mRelay test and fault reset: 0.6 N.mSensor: 0.6 N.mVoltage presence: 0.6 N.m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e9 mm pitches:\u003c\/th\u003e\n\u003ctd\u003e 8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth:\u003c\/th\u003e\n\u003ctd\u003e 71.2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight:\u003c\/th\u003e\n\u003ctd\u003e 98.7 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDepth:\u003c\/th\u003e\n\u003ctd\u003e 65.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight:\u003c\/th\u003e\n\u003ctd\u003e 0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIP degree of protection:\u003c\/th\u003e\n\u003ctd\u003e IP40 on front face: conforming to EN\/IEC 60529IP30 on side parts: conforming to EN\/IEC 60529IP20 on connection terminals: conforming to EN\/IEC 60529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIK degree of protection:\u003c\/th\u003e\n\u003ctd\u003e IK07 conforming to EN 50102\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMechanical robustness:\u003c\/th\u003e\n\u003ctd\u003e Fire resistance conforming to IEC 60695-2-1IK protection 2 joules: IK07 conforming to EN 50102Vibrations 13.2...100 Hz: 0.7 gVibrations 2...13.2 Hz: +\/- 1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCompatibility code:\u003c\/th\u003e\n\u003ctd\u003e RH197M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\n\u003cdiv class=\"section-additional\"\u003e\u003cdiv\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eOvervoltage category:\u003c\/th\u003e\n\u003ctd\u003e IV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical shock protection class:\u003c\/th\u003e\n\u003ctd\u003e Class II\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectromagnetic compatibility:\u003c\/th\u003e\n\u003ctd\u003e Conducted and radiated emissions: , B, conforming to CISPR 11Conducted radio-frequency immunity test: , 3, conforming to IEC 61000-4-6Electrostatic discharge immunity test: , 4, conforming to IEC 61000-4-2High-energy conducted susceptibility: , 4, conforming to IEC 61000-4-5Low-energy conducted susceptibility: , 4, conforming to IEC 61000-4-4Radiated susceptibility: , 3, conforming to IEC 61000-4-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative humidity:\u003c\/th\u003e\n\u003ctd\u003e 95 % at 55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePollution degree:\u003c\/th\u003e\n\u003ctd\u003e 3 conforming to IEC 60664-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient air temperature for operation:\u003c\/th\u003e\n\u003ctd\u003e -25...55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient air temperature for storage:\u003c\/th\u003e\n\u003ctd\u003e -40...85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEU RoHS Directive:\u003c\/th\u003e\n\u003ctd\u003e CompliantToxic heavy metal free\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\n\u003cdiv class=\"table-wrapper\" id=\"product-attributes\"\u003e\u003ctable class=\"additional-attributes w-full text-xs lg:text-xl\"\u003e \u003ctr class=\"\"\u003e\n\u003cth class=\"col label w-5\/12 lg:w-1\/4 py-1.5 text-left text-gray-600 font-normal align-top product-attribute-label\" scope=\"row\"\u003eCode EAN:\u003c\/th\u003e\n\u003ctd class=\"col data w-7\/12 lg:w-3\/4 py-1.5 pl-2 lg:pl-20 text-left product-attribute-value\" data-th=\"Code EAN\"\u003e3606480359743\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":44209767907382,"sku":"56517","price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0698\/4712\/1974\/files\/56517.png?v=1760128749","url":"https:\/\/www.tehonet.fi\/products\/schneider-electric-residual-current-protection-relay-vigirex-rh197m-30-ma-to-30-a-220-240-vac-50-60hz-alarm-50-or-100-din-rail-mounting-56517","provider":"TEHONET Power Electronics, Electrical \u0026 Automation equipment and components","version":"1.0","type":"link"}