{"product_id":"schneider-electric-tesys-d-contactor-4p-80a-ac-1-up-to-440v-coil-24v-dc-everlink-lc1dt80abbe","title":"TeSys D contactor 4P 80A AC-1 up to 440V coil 24V DC Everlink - LC1DT80ABBE","description":"\u003cdiv class=\"section-product-attributes\"\u003e \u003cdiv\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eRange:\u003c\/th\u003e\n\u003ctd\u003e TeSysTeSys Deca\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRange of product:\u003c\/th\u003e\n\u003ctd\u003e TeSys Deca\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct or component type:\u003c\/th\u003e\n\u003ctd\u003e Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDevice short name:\u003c\/th\u003e\n\u003ctd\u003e LC1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eContactor application:\u003c\/th\u003e\n\u003ctd\u003e Resistive load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUtilisation category:\u003c\/th\u003e\n\u003ctd\u003e AC-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePoles description:\u003c\/th\u003e\n\u003ctd\u003e 4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e[Ue] rated operational voltage:\u003c\/th\u003e\n\u003ctd\u003e Power circuit: \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e[Ie] rated operational current:\u003c\/th\u003e\n\u003ctd\u003e 80 A (at \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e[Uc] control circuit voltage:\u003c\/th\u003e\n\u003ctd\u003e 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"section-description\"\u003e\u003cdiv\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eCompatibility code:\u003c\/th\u003e\n\u003ctd\u003e LC1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePole contact composition:\u003c\/th\u003e\n\u003ctd\u003e 4 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtective cover:\u003c\/th\u003e\n\u003ctd\u003e With\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e[Ith] conventional free air thermal current:\u003c\/th\u003e\n\u003ctd\u003e 80 A (at 60 °C) for power circuit10 A (at 60 °C) for signalling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIrms rated making capacity:\u003c\/th\u003e\n\u003ctd\u003e 1000 A at 440 V for power circuit conforming to IEC 60947140 A AC for signalling circuit conforming to IEC 60947-5-1250 A DC for signalling circuit conforming to IEC 60947-5-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated breaking capacity:\u003c\/th\u003e\n\u003ctd\u003e 1000 A at 440 V for power circuit conforming to IEC 60947\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e[Icw] rated short-time withstand current:\u003c\/th\u003e\n\u003ctd\u003e 110 A 40 °C - 10 min for power circuit260 A 40 °C - 1 min for power circuit520 A 40 °C - 10 s for power circuit900 A 40 °C - 1 s for power circuit100 A - 1 s for signalling circuit120 A - 500 ms for signalling circuit140 A - 100 ms for signalling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAssociated fuse rating:\u003c\/th\u003e\n\u003ctd\u003e 125 A gG at 125 A gG at 10 A gG for signalling circuit conforming to IEC 60947-5-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAverage impedance:\u003c\/th\u003e\n\u003ctd\u003e 1.6 mOhm - Ith 80 A 50 Hz for power circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower dissipation per pole:\u003c\/th\u003e\n\u003ctd\u003e 10.2 W AC-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e[Ui] rated insulation voltage:\u003c\/th\u003e\n\u003ctd\u003e Power circuit: 690 V conforming to IEC 60947-4-1Signalling circuit: 690 V conforming to IEC 60947-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOvervoltage category:\u003c\/th\u003e\n\u003ctd\u003e III\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePollution degree:\u003c\/th\u003e\n\u003ctd\u003e 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e[Uimp] rated impulse withstand voltage:\u003c\/th\u003e\n\u003ctd\u003e 6 kV conforming to IEC 60947\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety reliability level:\u003c\/th\u003e\n\u003ctd\u003e B10d = 1369863 cycles contactor with nominal load conforming to EN\/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load conforming to EN\/ISO 13849-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMechanical durability:\u003c\/th\u003e\n\u003ctd\u003e 6 Mcycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical durability:\u003c\/th\u003e\n\u003ctd\u003e 0.5 Mcycles 80 A AC-1 at Ue \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eControl circuit type:\u003c\/th\u003e\n\u003ctd\u003e DC DC low consumption\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCoil technology:\u003c\/th\u003e\n\u003ctd\u003e Built-in bidirectional peak limiting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eControl circuit voltage limits:\u003c\/th\u003e\n\u003ctd\u003e 0.8...1.2 Uc (-40...60 °C):operational DC1...1.2 Uc (60...70 °C):operational DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInrush power in W:\u003c\/th\u003e\n\u003ctd\u003e 11 W (at 20 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHold-in power consumption in W:\u003c\/th\u003e\n\u003ctd\u003e 0.5 W at 20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeat dissipation:\u003c\/th\u003e\n\u003ctd\u003e 0.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating time:\u003c\/th\u003e\n\u003ctd\u003e 55...65 ms closing20...80 ms opening\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum operating rate:\u003c\/th\u003e\n\u003ctd\u003e 3600 cyc\/h 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnections - terminals:\u003c\/th\u003e\n\u003ctd\u003e Control circuit: screw clamp terminals 1 1...4 mm² - cable stiffness: flexible without cable endControl circuit: screw clamp terminals 2 1...4 mm² - cable stiffness: flexible without cable endControl circuit: screw clamp terminals 1 1...4 mm² - cable stiffness: flexible with cable endControl circuit: screw clamp terminals 2 1...2.5 mm² - cable stiffness: flexible with cable endControl circuit: screw clamp terminals 1 1...4 mm² - cable stiffness: solidControl circuit: screw clamp terminals 2 1...4 mm² - cable stiffness: solidPower circuit: EverLink BTR screw connectors 1 1...35 mm² - cable stiffness: flexible without cable endPower circuit: EverLink BTR screw connectors 1 1...35 mm² - cable stiffness: flexible with cable endPower circuit: EverLink BTR screw connectors 1 1...35 mm² - cable stiffness: solidPower circuit: EverLink BTR screw connectors 2 1...25 mm² - cable stiffness: flexible without cable endPower circuit: EverLink BTR screw connectors 2 1...25 mm² - cable stiffness: flexible with cable endPower circuit: EverLink BTR screw connectors 2 1...25 mm² - cable stiffness: solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTightening torque:\u003c\/th\u003e\n\u003ctd\u003e Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mmControl circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2Power circuit: 8 N.m - on EverLink BTR screw connectors - cable 25...35 mm² hexagonal screw head 4 mmPower circuit: 5 N.m - on EverLink BTR screw connectors - cable 1...25 mm² hexagonal screw head 4 mmPower circuit: 5 N.m - with screwdriver pozidriv No 2Control circuit: 1.7 N.m - with screwdriver pozidriv No 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAuxiliary contact composition:\u003c\/th\u003e\n\u003ctd\u003e 1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAuxiliary contacts type:\u003c\/th\u003e\n\u003ctd\u003e  type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 type mirror contact 1 NC conforming to IEC 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSignalling circuit frequency:\u003c\/th\u003e\n\u003ctd\u003e 25...400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMinimum switching voltage:\u003c\/th\u003e\n\u003ctd\u003e 17 V for signalling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMinimum switching current:\u003c\/th\u003e\n\u003ctd\u003e 5 mA for signalling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsulation resistance:\u003c\/th\u003e\n\u003ctd\u003e \u0026gt; 10 MOhm for signalling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNon-overlap time:\u003c\/th\u003e\n\u003ctd\u003e 1.5 ms on de-energisation between NC and NO contact1.5 ms on energisation between NC and NO contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting support:\u003c\/th\u003e\n\u003ctd\u003e PlateRail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\n\u003cdiv class=\"section-additional\"\u003e\u003cdiv\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eStandards:\u003c\/th\u003e\n\u003ctd\u003e EN\/IEC 60947-4-1EN\/IEC 60947-5-1UL 60947-4-1CSA C22.2 No 60947-4-1IEC 60335-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct certifications:\u003c\/th\u003e\n\u003ctd\u003e CCCCSAEACULKCDNV-GLLROS (Lloyds register of shipping)UKCA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIP degree of protection:\u003c\/th\u003e\n\u003ctd\u003e IP20 front face conforming to IEC 60529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eClimatic withstand:\u003c\/th\u003e\n\u003ctd\u003e  conforming to IACS E10 exposure to damp heat conforming to IEC 60947-1 Annex Q category D exposure to damp heat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePermissible ambient air temperature around the device:\u003c\/th\u003e\n\u003ctd\u003e -40...60 °C60...70 °C with derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating altitude:\u003c\/th\u003e\n\u003ctd\u003e 0...3000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFire resistance:\u003c\/th\u003e\n\u003ctd\u003e 850 °C conforming to IEC 60695-2-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlame retardance:\u003c\/th\u003e\n\u003ctd\u003e V1 conforming to UL 94\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMechanical robustness:\u003c\/th\u003e\n\u003ctd\u003e Vibrations contactor open (2 Gn, 5...300 Hz) Vibrations contactor closed (4 Gn, 5...300 Hz) Shocks contactor open (10 Gn for 11 ms) Shocks contactor closed (15 Gn for 11 ms) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight:\u003c\/th\u003e\n\u003ctd\u003e 122 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth:\u003c\/th\u003e\n\u003ctd\u003e 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDepth:\u003c\/th\u003e\n\u003ctd\u003e 120 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNet weight:\u003c\/th\u003e\n\u003ctd\u003e 1.290 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSustainable offer status:\u003c\/th\u003e\n\u003ctd\u003e Green Premium productREACh Regulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnit Type of Package 1:\u003c\/th\u003e\n\u003ctd\u003e PCENumber of Units in Package 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\n\u003cdiv class=\"table-wrapper\" id=\"product-attributes\"\u003e\u003ctable class=\"additional-attributes w-full text-xs lg:text-xl\"\u003e \u003ctr class=\"\"\u003e\n\u003cth class=\"col label w-5\/12 lg:w-1\/4 py-1.5 text-left text-gray-600 font-normal align-top product-attribute-label\" scope=\"row\"\u003eCode EAN:\u003c\/th\u003e\n\u003ctd class=\"col data w-7\/12 lg:w-3\/4 py-1.5 pl-2 lg:pl-20 text-left product-attribute-value\" data-th=\"Code EAN\"\u003e3606489493578\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":44209850351670,"sku":"LC1DT80ABBE","price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0698\/4712\/1974\/files\/LC1DT80ABBE_2.png?v=1760130215","url":"https:\/\/www.tehonet.fi\/products\/schneider-electric-tesys-d-contactor-4p-80a-ac-1-up-to-440v-coil-24v-dc-everlink-lc1dt80abbe","provider":"TEHONET Power Electronics, Electrical \u0026 Automation equipment and components","version":"1.0","type":"link"}