{"product_id":"schneider-electric-tesys-gv4-magnetic-circuit-breaker-80a-3p-with-everlink-gv4le80b","title":"TeSys GV4 - magnetic circuit breaker - 80A 3P - with EverLink - GV4LE80B","description":"\u003cdiv class=\"section-product-attributes\"\u003e \u003cdiv\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eRange:\u003c\/th\u003e\n\u003ctd\u003e TeSys DecaTeSys Deca\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRange of product:\u003c\/th\u003e\n\u003ctd\u003e TeSys GV4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDevice short name:\u003c\/th\u003e\n\u003ctd\u003e GV4L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct name:\u003c\/th\u003e\n\u003ctd\u003e TeSys GV4TeSys Deca\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct or component type:\u003c\/th\u003e\n\u003ctd\u003e Motor circuit breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDevice application:\u003c\/th\u003e\n\u003ctd\u003e Motor protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTrip unit technology:\u003c\/th\u003e\n\u003ctd\u003e MagneticElectronic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"section-description\"\u003e\u003cdiv\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003ePoles description:\u003c\/th\u003e\n\u003ctd\u003e 3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUtilisation category:\u003c\/th\u003e\n\u003ctd\u003e Category A conforming to IEC 60947-2AC-3 conforming to IEC 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating position:\u003c\/th\u003e\n\u003ctd\u003e Any position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor power kW:\u003c\/th\u003e\n\u003ctd\u003e 37 kW at 400...415 V AC 50\/60 Hz45 kW at 500 V AC 50\/60 Hz55 kW at 500 V AC 50\/60 Hz22 kW at 400...415 V AC 50\/60 Hz30 kW at 500 V AC 50\/60 Hz37 kW at 660...690 V AC 50\/60 Hz45 kW at 660...690 V AC 50\/60 Hz55 kW at 660...690 V AC 50\/60 Hz30 kW at 400...415 V AC 50\/60 Hz37 kW at 500 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBreaking capacity:\u003c\/th\u003e\n\u003ctd\u003e 50 kA Icu at 220...240 V AC 50\/60 Hz conforming to IEC 60947-225 kA Icu at 380...415 V AC 50\/60 Hz conforming to IEC 60947-220 kA Icu at 440 V AC 50\/60 Hz conforming to IEC 60947-210 kA Icu at 500 V AC 50\/60 Hz conforming to IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eControl type:\u003c\/th\u003e\n\u003ctd\u003e Toggle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e[In] rated current:\u003c\/th\u003e\n\u003ctd\u003e 80 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMagnetic tripping current:\u003c\/th\u003e\n\u003ctd\u003e 480...1120 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e[Ue] rated operational voltage:\u003c\/th\u003e\n\u003ctd\u003e 690 V AC 50\/60 Hz conforming to IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e[Ui] rated insulation voltage:\u003c\/th\u003e\n\u003ctd\u003e 800 V AC 50\/60 Hz conforming to IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e[Ith] conventional free air thermal current:\u003c\/th\u003e\n\u003ctd\u003e 115 A conforming to IEC 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e[Uimp] rated impulse withstand voltage:\u003c\/th\u003e\n\u003ctd\u003e 8 kV conforming to IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower dissipation per pole:\u003c\/th\u003e\n\u003ctd\u003e 6.1 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMechanical durability:\u003c\/th\u003e\n\u003ctd\u003e 40000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical durability:\u003c\/th\u003e\n\u003ctd\u003e 14000 cycles for AC-3 at 440 V In\/27000 cycles for AC-3 at 440 V In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum operating rate:\u003c\/th\u003e\n\u003ctd\u003e 25 cyc\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated duty:\u003c\/th\u003e\n\u003ctd\u003e Continuous conforming to IEC 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDirect connector:\u003c\/th\u003e\n\u003ctd\u003e Without\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnections - terminals:\u003c\/th\u003e\n\u003ctd\u003e EverLink BTR screw connectors (top) 1 cable(s) 1.5...70 mm² - solidEverLink BTR screw connectors (top) 1 cable(s) 1.5...50 mm² - flexibleEverLink BTR screw connectors (bottom) 1 cable(s) 2.5...95 mm² - solidEverLink BTR screw connectors (bottom) 1 cable(s) 2.5...70 mm² - flexible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTightening torque:\u003c\/th\u003e\n\u003ctd\u003e 9 N.m for cable 16...95 mm²5 N.m for cable 1.5...10 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMechanical robustness:\u003c\/th\u003e\n\u003ctd\u003e Vibrations: +\/- 1 mm 2...13.2 Hz conforming to IEC 60068-2-6Vibrations: 0.7 gn 13.2...100 Hz conforming to IEC 60068-2-6Shocks: 15 gn 11 ms conforming to IEC 60068-2-27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight:\u003c\/th\u003e\n\u003ctd\u003e 155 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth:\u003c\/th\u003e\n\u003ctd\u003e 81 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDepth:\u003c\/th\u003e\n\u003ctd\u003e 116 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNet weight:\u003c\/th\u003e\n\u003ctd\u003e 1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eColour:\u003c\/th\u003e\n\u003ctd\u003e Grey (RAL 7016)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSuitability for isolation:\u003c\/th\u003e\n\u003ctd\u003e Yes conforming to IEC 60947-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\n\u003cdiv class=\"section-additional\"\u003e\u003cdiv\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eStandards:\u003c\/th\u003e\n\u003ctd\u003e EN\/IEC 60947-4-1EN\/IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct certifications:\u003c\/th\u003e\n\u003ctd\u003e IECCCCEACEU-RO MR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eClimatic withstand:\u003c\/th\u003e\n\u003ctd\u003e  conforming to IACS E10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIK degree of protection:\u003c\/th\u003e\n\u003ctd\u003e IK07 conforming to IEC 62262\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePollution degree:\u003c\/th\u003e\n\u003ctd\u003e 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIP degree of protection:\u003c\/th\u003e\n\u003ctd\u003e IP40 conforming to IEC 60529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient air temperature for storage:\u003c\/th\u003e\n\u003ctd\u003e -50...85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFire resistance:\u003c\/th\u003e\n\u003ctd\u003e 960 °C conforming to IEC 60695-2-11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating altitude:\u003c\/th\u003e\n\u003ctd\u003e 5000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient air temperature for operation:\u003c\/th\u003e\n\u003ctd\u003e -25...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSustainable offer status:\u003c\/th\u003e\n\u003ctd\u003e Green Premium productREACh Regulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnit Type of Package 1:\u003c\/th\u003e\n\u003ctd\u003e PCENumber of Units in Package 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\n\u003cdiv class=\"table-wrapper\" id=\"product-attributes\"\u003e\u003ctable class=\"additional-attributes w-full text-xs lg:text-xl\"\u003e \u003ctr class=\"\"\u003e\n\u003cth class=\"col label w-5\/12 lg:w-1\/4 py-1.5 text-left text-gray-600 font-normal align-top product-attribute-label\" scope=\"row\"\u003eCode EAN:\u003c\/th\u003e\n\u003ctd class=\"col data w-7\/12 lg:w-3\/4 py-1.5 pl-2 lg:pl-20 text-left product-attribute-value\" data-th=\"Code EAN\"\u003e3606481309457\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":44209863327798,"sku":"GV4LE80B","price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0698\/4712\/1974\/files\/GV4LE80B_3.png?v=1760130515","url":"https:\/\/www.tehonet.fi\/products\/schneider-electric-tesys-gv4-magnetic-circuit-breaker-80a-3p-with-everlink-gv4le80b","provider":"TEHONET Power Electronics, Electrical \u0026 Automation equipment and components","version":"1.0","type":"link"}