{"product_id":"schneider-electric-thermal-magnetic-circuit-breaker-tesys-gb2-1p-3-a-icu-3-ka-240-v-gb2cb08","title":"Thermal magnetic circuit breaker, TeSys GB2, 1P, 3 A, Icu 3 kA@240 V - GB2CB08","description":"\u003cdiv class=\"section-product-attributes\"\u003e \u003cdiv\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eRange:\u003c\/th\u003e\n\u003ctd\u003e TeSys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct name:\u003c\/th\u003e\n\u003ctd\u003e TeSys GB2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDevice short name:\u003c\/th\u003e\n\u003ctd\u003e GB2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct or component type:\u003c\/th\u003e\n\u003ctd\u003e Circuit breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDevice application:\u003c\/th\u003e\n\u003ctd\u003e Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePoles description:\u003c\/th\u003e\n\u003ctd\u003e 1P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNetwork type:\u003c\/th\u003e\n\u003ctd\u003e AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUtilisation category:\u003c\/th\u003e\n\u003ctd\u003e Category A conforming to IEC 60947-2DC-12 conforming to IEC 60947-5-1DC-13 conforming to IEC 60947-5-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNetwork frequency:\u003c\/th\u003e\n\u003ctd\u003e 50\/60 Hz conforming to IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBreaking capacity:\u003c\/th\u003e\n\u003ctd\u003e 10 kA Icu at 110 V AC 50\/60 Hz conforming to IEC 60947-23 kA Icu at 230\/240 V AC 50\/60 Hz conforming to IEC 60947-21.5 kA Icu at 24 V DC conforming to IEC 60947-21 kA Icu at 48 V DC conforming to IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e[Ics] rated service short-circuit breaking capacity:\u003c\/th\u003e\n\u003ctd\u003e 50 % at 110 V AC 50\/60 Hz conforming to IEC 60947-250 % at 230\/240 V AC 50\/60 Hz conforming to IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTrip unit technology:\u003c\/th\u003e\n\u003ctd\u003e Thermal-magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMagnetic tripping current:\u003c\/th\u003e\n\u003ctd\u003e 40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"section-description\"\u003e\u003cdiv\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting mode:\u003c\/th\u003e\n\u003ctd\u003e By clips\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting support:\u003c\/th\u003e\n\u003ctd\u003e PlateRail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting position:\u003c\/th\u003e\n\u003ctd\u003e VerticalHorizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eControl type:\u003c\/th\u003e\n\u003ctd\u003e Toggle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e[In] rated current:\u003c\/th\u003e\n\u003ctd\u003e 3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e[Ue] rated operational voltage:\u003c\/th\u003e\n\u003ctd\u003e 250 V AC 50\/60 Hz conforming to IEC 60947-2277 V AC 60 Hz conforming to CSA C22.2 No 235277 V AC 60 Hz conforming to UL 107748 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e[Uimp] rated impulse withstand voltage:\u003c\/th\u003e\n\u003ctd\u003e 4 kV conforming to IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower dissipation per pole:\u003c\/th\u003e\n\u003ctd\u003e 2 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMechanical durability:\u003c\/th\u003e\n\u003ctd\u003e 8000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical durability:\u003c\/th\u003e\n\u003ctd\u003e 8000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnections - terminals:\u003c\/th\u003e\n\u003ctd\u003e Connector 1 cable(s) 0.75...6 mm²solid without cable endConnector 2 cable(s) 0.75...4 mm²solid without cable endConnector 1 cable(s) 0.75...4 mm²flexible with cable endConnector 2 cable(s) 0.75...2.5 mm²flexible with cable end\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTightening torque:\u003c\/th\u003e\n\u003ctd\u003e 1.2 N.m on connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMechanical robustness:\u003c\/th\u003e\n\u003ctd\u003e Shocks: 22 Gn for 20 ms conforming to IEC 60068-2-27Vibrations: 5 Gn, 5...110 Hz conforming to IEC 60068-2-6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eQuantity per set:\u003c\/th\u003e\n\u003ctd\u003e Set of 6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e9 mm pitches:\u003c\/th\u003e\n\u003ctd\u003e 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight:\u003c\/th\u003e\n\u003ctd\u003e 74 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth:\u003c\/th\u003e\n\u003ctd\u003e 15 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDepth:\u003c\/th\u003e\n\u003ctd\u003e 67 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCompatibility code:\u003c\/th\u003e\n\u003ctd\u003e GB2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\n\u003cdiv class=\"section-additional\"\u003e\u003cdiv\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eStandards:\u003c\/th\u003e\n\u003ctd\u003e EN\/IEC 60947-1EN\/IEC 60947-2CSA C22.2 No 235UL 1077\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct certifications:\u003c\/th\u003e\n\u003ctd\u003e ULCSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtective treatment:\u003c\/th\u003e\n\u003ctd\u003e TC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIP degree of protection:\u003c\/th\u003e\n\u003ctd\u003e IP20 conforming to IEC 60529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient air temperature for operation:\u003c\/th\u003e\n\u003ctd\u003e -20...60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient air temperature for storage:\u003c\/th\u003e\n\u003ctd\u003e -40...80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFire resistance:\u003c\/th\u003e\n\u003ctd\u003e 960 °C conforming to IEC 60695-2-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating altitude:\u003c\/th\u003e\n\u003ctd\u003e 3000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSustainable offer status:\u003c\/th\u003e\n\u003ctd\u003e Green Premium productREACh Regulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\n\u003cdiv class=\"table-wrapper\" id=\"product-attributes\"\u003e\u003ctable class=\"additional-attributes w-full text-xs lg:text-xl\"\u003e \u003ctr class=\"\"\u003e\n\u003cth class=\"col label w-5\/12 lg:w-1\/4 py-1.5 text-left text-gray-600 font-normal align-top product-attribute-label\" scope=\"row\"\u003eCode EAN:\u003c\/th\u003e\n\u003ctd class=\"col data w-7\/12 lg:w-3\/4 py-1.5 pl-2 lg:pl-20 text-left product-attribute-value\" data-th=\"Code EAN\"\u003e3389110214628\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":44210578489398,"sku":"GB2CB08","price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0698\/4712\/1974\/files\/GB2CB08.jpg?v=1760155519","url":"https:\/\/www.tehonet.fi\/products\/schneider-electric-thermal-magnetic-circuit-breaker-tesys-gb2-1p-3-a-icu-3-ka-240-v-gb2cb08","provider":"TEHONET Power Electronics, Electrical \u0026 Automation equipment and components","version":"1.0","type":"link"}