Schneider Electric SCHNEIDER Miniature circuit-breaker, Acti9 iC60N, 2P, 10 A, C curve, 6000 A (IEC 60898-1), 10 kA (IEC 60947-2) - A9F77210
Schneider Electric SCHNEIDER Miniature circuit-breaker, Acti9 iC60N, 2P, 10 A, C curve, 6000 A (IEC 60898-1), 10 kA (IEC 60947-2) - A9F77210

Miniature circuit-breaker, Acti9 iC60N, 2P, 10 A, C curve, 6000 A (IEC 60898-1), 10 kA (IEC 60947-2) - A9F77210

SKU : A9F77210

Regular price €0,00


/

Contact us for price and lead time for this product. Our team will respond quickly.

Lead time: 2–3 weeks – Ships quickly after order confirmation

Miniature circuit-breaker, Acti9 iC60N, 2P, 10 A, C curve, 6000 A (IEC 60898-1), 10 kA (IEC 60947-2) - A9F77210

DESCRIPTION

    • Main
      • device application : Distribution
      • range : Acti 9
      • range of product : IC60
      • product name : Acti 9 iC60
      • product or component type : Miniature circuit-breaker
      • device short name : IC60N
      • poles description : 2P
      • number of protected poles : 2
      • [In] rated current : 10 A
      • network type : DC AC
      • trip unit technology : Thermal-magnetic
      • curve code : C
      • breaking capacity code : N
      • breaking capacity: 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
  • 36 kA Icu at 12... 60 V AC 50/60 Hz conforming to EN/IEC 60947-2
  • 10 kA Icu at <= 125 V DC conforming to EN/IEC 60947-2
  • 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2
  • 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2
  • 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2
  • 36 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2
      • use category : Category A conforming to EN 60947-2
      • Category A conforming to IEC 60947-2
      • suitability for isolation : Yes conforming to EN 60898-1
      • Yes conforming to EN 60947-2
      • Yes conforming to IEC 60898-1
      • Yes conforming to IEC 60947-2
      • standards : EN 60947-2
  • EN 60898-1
  • IEC 60898-1
  • IEC 60947-2
      • quality labels : NF

The iC60 Acti9 modular circuit breaker is the new benchmark in low-voltage terminal distribution for circuit protection. Thanks to its exclusive features, it offers absolute safety and improved service continuity: iClass 2 insulation, VISI-TRIP: rapid detection of faults, harsh environments: ‘Si’ type device fully immune to electrical disturbances.

    • Rated current: 1 to 63 A and breaking capacity up to 100 kA
    • Operating voltage: up to 440 Vac, insulation voltage: 500V, pollution degree: level 3.
    • Auxiliaries: status and trip indicator, voltage emission trip, undervoltage trip, overvoltage trip.
  • Environmental characteristics
      • Period : 18 months
      • Environmental status : Green Premium product
      • RoHS (code date: YearWeek) : Compliant - since 1001 - Schneider Electric declaration of conformity
      • REACh : Reference not containing SVHC above the threshold
      • Product environmental profile : Available
      • End-of-life instructions for the product : No specific recycling operations
      • Device function : Distribution
      • Range : Acti 9
      • Product function : Miniature circuit breaker
      • Product name : IC60
      • Abbreviated device name : IC60N
      • Pole description : 2P
      • Number of protected poles : 2
      • Rated operating current : 10 A
      • Network type : AC DC
      • Trigger technology : Thermal-magnetic
      • Trigger curve : C
      • Breaking capacity : 36 kA Icu in accordance with EN 60947-2 - 12...133 V AC 50/60 Hz
      • 36 kA Icu in accordance with IEC 60947-2 - 12...133 V AC 50/60 Hz
      • 6 kA Icu in accordance with IEC 60947-2 - 440 V AC 50/60 Hz
      • 6 kA Icu in accordance with EN 60947-2 - 440 V AC 50/60 Hz
      • 20 kA Icu in accordance with IEC 60947-2 - 220... 240 V AC 50/60 Hz
      • 20 kA Icu in accordance with EN 60947-2 - 220...240 V AC 50/60 Hz
      • 10 kA Icu in accordance with IEC 60947-2 - 380...415 V AC 50/60 Hz
      • 10 kA Icu in accordance with EN 60947-2 - 380...415 V AC 50/60 Hz
      • 10 kA Icu in accordance with IEC 60947-2 - 72...125 V DC
      • 10 kA Icu in accordance with EN 60947-2 - 72... 125 V DC
      • 6000 A Icn in accordance with IEC 60898-1 - 400 V AC 50/60 Hz
      • 6000 A Icn in accordance with EN 60898-1 - 400 V AC 50/60 Hz
      • Category of use : A in accordance with IEC 60947-2
      • A in accordance with EN 60947-2
      • Switching capability : Yes in accordance with IEC 60947-2
      • Yes in accordance with IEC 60898-1
      • Yes in accordance with EN 60947-2
      • Yes in accordance with EN 60898-1
      • Standards : EN 60898-1
      • EN 60947-2
      • IEC 60898-1
      • IEC 60947-2
      • Quality labels : NF
      • Mains frequency : 50/60 Hz
      • Magnetic trip limit : 8 x In +/- 20%
      • [Ics] rated short-circuit breaking capacity : 10 kA 100% x Icu in accordance with EN 60947-2 - 72...125 V DC
      • 10 kA 100% x Icu in accordance with IEC 60947-2 - 72...125 V DC
      • 6000 A 100% x Icu in accordance with IEC 60898-1 - 400 V AC 50/60 Hz
      • 6000 A 100% x Icu in accordance with EN 60898-1 - 400 V AC 50/60 Hz
      • 27 kA 0.75 x Icu in accordance with EN 60947-2 - 12...133 V AC 50/60 Hz
      • 27 kA 0.75 x Icu in accordance with IEC 60947-2 - 12...133 V AC 50/60 Hz
      • 4.5 kA 0.75 x Icu in accordance with IEC 60947-2 - 440 V AC 50/60 Hz
      • 7.5 kA 0.75 x Icu in accordance with IEC 60947-2 - 380...415 V AC 50/60 Hz
      • 15 kA 0.75 x Icu in accordance with IEC 60947-2 - 220...240 V AC 50/60 Hz
      • 4.5 kA 0.75 x Icu in accordance with EN 60947-2 - 440 V AC 50/60 Hz
      • 7.5 kA 0.75 x Icu in accordance with EN 60947-2 - 380...415 V AC 50/60 Hz
      • 15 kA 0.75 x Icu in accordance with EN 60947-2 - 220...240 V AC 50/60 Hz
      • Limitation class : 3 in accordance with IEC 60898-1
      • 3 in accordance with EN 60898-1
      • [Ui] rated insulation voltage : 500 V AC 50/60 Hz in accordance with IEC 60947-2
      • 500 V AC 50/60 Hz in accordance with EN 60947-2
      • [Uimp] rated impulse withstand voltage : 6 kV in accordance with IEC 60947-2
      • 6 kV in accordance with EN 60947-2
      • Fully visible break : Yes
      • Type of control : By cam
      • Local signalling : Trip indicator
      • Installation mode : Fixed
      • Mounting bracket : DIN rail
      • Compatibility of busbar comb distribution block : Yes, top or bottom
      • 9 mm pitch : 4
      • Height : 85 mm
      • Width : 36 mm
      • Depth : 78.5 mm
      • Weight : 0.25 kg
      • Colour : White
      • Mechanical life : 20,000 cycles
      • Electrical life : 10,000 cycles
      • Connection method : Single terminal, top or bottom flexible wire(s) 1...16 mm² max
      • Single terminal, top or bottom rigid wire(s) 1...25 mm² max
      • Wire stripping length : 14 mm top or bottom
      • Tightening torque : 2 N.m top or bottom
      • Earth leakage protection : Separate bloc
Code EAN: 3606480094125
Rappels: This Schneider A9F77210 circuit breaker is a miniature circuit breaker from the Acti9 range, iC60N 2P 10A C-curve circuit breaker - A9F77210. It protects 2P and has a thermal-magnetic trip type. It has a consumption of 10 A and a C curve trip designed for the following applications: general applications. The breaking capacity is 20 kA at 220...240 V and 10 kA at 380...415 V. We confirm that this circuit breaker occupies two modules in width and can be housed in a cabinet or box. It can be connected with rigid wires of 25 mm² max. or flexible wires of 16 mm² max.