website Skip to content
English
  • Language EnglishEnglish
  • Language SuomiSuomi
  • Language SvenskaSvenska
EUR
  • GBP
  • USD
  • EUR
Schneider Electric PowerLogic PowerLogic PM8000 - PM8240 Panel mount meter - intermediate metering - METSEPM8240
Schneider Electric PowerLogic PowerLogic PM8000 - PM8240 Panel mount meter - intermediate metering - METSEPM8240

PowerLogic PM8000 - PM8240 Panel mount meter - intermediate metering - METSEPM8240

SKU : METSEPM8240

Regular price €0,00


/

Contact us for price and lead time for this product. Our team will respond quickly.

Lead time: 2–3 weeks – Ships quickly after order confirmation

PowerLogic PM8000 - PM8240 Panel mount meter - intermediate metering - METSEPM8240

DESCRIPTION

Range: PowerLogic
Product name: PowerLogic PM8000
Device short name: PM8240
Product or component type: Power meter
Market segment: Buildings large building cost management: billing: sub feederBuildings small building network management: main incomerBuildings medium building network management: main incomerBuildings large building network management: main incomerBuildings large building network management: sub feederBuildings multi-site network management: main incomerBuildings multi-site network management: sub feederData center network management: main incomerData center network management: sub feederHealthcare network management: main incomerHealthcare network management: sub feederIndustry network management: main incomerIndustry network management: sub feederUtility: sub feeder
Power quality analysis: conforming to EN 50160: 2010 compliance report conforming to IEEE 519: 2014 compliance report conforming to IEC 61000-4-30: class S power quality measurement up to the 63rd harmonic harmonic distortion waveform capture voltage sag and swell detection programmablity (logic and math functions) conforming to IEC 62586 power quality monitoring
Device application: Power monitoringWAGES metering
Type of measurement: CurrentVoltageFrequencyActive and reactive power totalApparent power totalPower factor totalActive and reactive power per phase, rmsApparent power per phase, rmsPower factor per phase, rms
[Us] rated supply voltage: 90...415 V AC 45...65 Hz +/- 10 %110...415 V DC +/- 10 %
Network frequency: 50 Hz60 Hz
[In] rated current: 1 A5 A10 A
Poles description: 3P + N3P1P + N
Power consumption in VA: 18 VA at 415 V AC
Display type: Colour TFT LCD
Display resolution: 320 x 240 pixels QVGA
Sampling rate: 256 samples/cycle
Measurement current: 50...10000 mA
Analogue input type: Voltage (impedance 5 MOhm)Current (impedance 0.3 mOhm)
Measurement voltage: 57...400 V AC 42...69 Hz between phase and neutral100...690 V AC 42...69 Hz between phases
Frequency measurement range: 42...69 Hz
Number of inputs: 3 digital 30 V AC3 digital 60 V DC
Measurement accuracy: Current +/- 0.1 %Voltage +/- 0.1 %Active energy +/- 0.2 %
Accuracy class: Class 0.2S active energy conforming to IEC 62053-22Class 0.2 active energy conforming to ANSI C12.20Class 0.2 active power conforming to IEC 61557-12Class 0.5S reactive energy conforming to IEC 62053-24Class 0.5 power factor conforming to IEC 61557-12Class 0.2 voltage conforming to IEC 61557-12Class 0.2 current conforming to IEC 61557-12
Number of outputs: 1 pulse
Information displayed: VoltageCurrentFrequencyPowerEnergy consumptionHarmonic distortion
Communication port protocol: Modbus RTU at 115 kbauds - 2-wireION at 115 kbauds - 2-wireDNP3IEC 61850Modbus TCP/IPEthernet Modbus TCP/IP daisy chain at 10/100 Mbit/sRSTP 801.1d 2004
Communication port support: EthernetScrew terminal block: RS485
Communication network type: IPv6 (internet protocol)
Data recording: Min/max of instantaneous valuesWaveform logsSequence of event recordingTime stampingAlarm logsTrending/forecastingSag and swell logsHarmonics logsGPS synchronisationData logsEvent logs
Memory capacity: 512 MB
Web services: Customizable home pageFile upload/download via FTPFile upload/download via SFTPWeb serverAlarm notification by e-mailViewing of captured waveform (FTP)Viewing of captured waveform (web)HTTPS server
Communication service: SMTP e-mail notificationRSTP supportNTP time synchronizationDHCPPTP time synchronization
Cybersecurity: Enable/disable communication portsPassword protectionSyslog protocol supportRobust security logsPort hardening
Mounting mode: Flush-mounted
Mounting support: Framework
Installation category: III
Isolation voltage: III400...690 V conforming to IEC 61010-1:ed. 3III400...690 V conforming to EN 61010-1:ed. 3III347...600 V conforming to UL 61010-1:ed. 3III347...600 V conforming to CSA C22.2 No 61010-1:ed. 3
Standards: IEC 61557-12IEC 62052-11IEC 62053-24IEC 62053-22IEEE 1588IEC 62586-2IEC 61326-1
Product certifications: CECULusN998
Width: 96 mm
Depth: 77.5 mm
Height: 96 mm
Product weight: 581 g
Electromagnetic compatibility: Electrostatic discharge conforming to IEC 61000-4-2Radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3Electrical fast transient/burst immunity test conforming to IEC 61000-4-4Surge immunity test conforming to IEC 61000-4-5Conducted RF disturbances conforming to IEC 61000-4-6Magnetic field at power frequency conforming to IEC 61000-4-8Voltage dips and interruptions immunity test conforming to IEC 61000-4-11Immunity to impulse waves conforming to IEC 61000-4-12Conducted and radiated emissions conforming to EN 55022Conducted and radiated emissions conforming to EN 55011Conducted and radiated emissions conforming to FCC part 15Conducted and radiated emissions conforming to ICES-003Conducted RF disturbances (2...150 Hz) conforming to CLC/TR 50579Surge withstand conforming to IEEE C37.90.1
IP degree of protection: IP54 front: conforming to IEC 60529IP30 body: conforming to IEC 60529
Relative humidity: 5...95 %
Ambient air temperature for operation: -25...70 °C
Ambient air temperature for storage: -40...85 °C
Operating altitude: 3000 m
Compatibility code: PM8240
Sustainable offer status: Green Premium productREACh Regulation
Code EAN: 3606480701931