website Skip to content
English
  • Language EnglishEnglish
  • Language SuomiSuomi
  • Language SvenskaSvenska
EUR
  • GBP
  • USD
  • EUR
Schneider Electric SCHNEIDER Télémécanique - Limit switch body ZCKJ - fixed - w/o display - 1NC+1NO - snap action - M20 - ZCKJ1H29
Schneider Electric SCHNEIDER Télémécanique - Limit switch body ZCKJ - fixed - w/o display - 1NC+1NO - snap action - M20 - ZCKJ1H29

Télémécanique - Limit switch body ZCKJ - fixed - w/o display - 1NC+1NO - snap action - M20 - ZCKJ1H29

SKU : ZCKJ1H29

Regular price €0,00


/

Contact us for price and lead time for this product. Our team will respond quickly.

Lead time: 2–3 weeks – Ships quickly after order confirmation

Télémécanique - Limit switch body ZCKJ - fixed - w/o display - 1NC+1NO - snap action - M20 - ZCKJ1H29

DESCRIPTION

Range of product: Telemecanique Limit switches XC Standard
Series name: Standard format
Product or component type: Limit switch body
Device short name: ZCKJ
Body type: Fixed
Product compatibility: XCKJ
Associated head: ZCKE61ZCKE05ZCKE06ZCKE67ZCKE08ZCKE21ZCKE65ZCKE629ZCKE62ZCKE63ZCKE66ZCKE64ZCKE23ZCKE619
Body material: Metal
Cable entry: 1 entry tapped for M20 x 1.5 cable gland
Number of poles: 2
Contacts type and composition: 1 NC + 1 NO
Contact operation: Snap action
Number of steps: 1 1 position
Contacts material: Silver plated contacts
Local display: Without
Electrical connection: Screw-clamp terminals, clamping capacity: 1 x 0.34...2 x 1.5 mm²
Positive opening: With
Minimum actuation speed: 0.01 m/min
[Ie] rated operational current: 3 A at 240 V, AC-15, A300 conforming to EN/IEC 60947-5-1 appendix A0.27 A at 250 V, DC-13, Q300 conforming to EN/IEC 60947-5-1 appendix A
[Ithe] conventional enclosed thermal current: 10 A
[Ui] rated insulation voltage: 500 V (pollution degree 3) conforming to IEC 60947-1 for contact block300 V conforming to CSA C22.2 No 14 for contact block300 V conforming to UL 508 for contact block
Maximum resistance across terminals: 0.25 mOhm conforming to IEC 60255-7 category 3
[Uimp] rated impulse withstand voltage: 6 kV conforming to IEC 606646 kV conforming to IEC 60947-1
Short-circuit protection: 10 A cartridge fuse, type gG
Electrical durability: 5000000 cycles, DC-13 120 V, 4 W, operating rate 5000000 cycles, DC-13 24 V, 10 W, operating rate 5000000 cycles, DC-13 48 V, 7 W, operating rate
Width: 43 mm
Height: 84 mm
Depth: 36 mm
Product weight: 0.3 kg
Terminals description ISO n°1: (21-22)NC(13-14)NO(23-24)NO(11-12)NC
Device presentation: Basic element
Compatibility code: ZCKJ
IP degree of protection: IP66
IK degree of protection: IK07
Ambient air temperature for operation: 10...120 °C for high temperature
Ambient air temperature for storage: 10...120 °C
Environmental characteristic: High temperature
Sustainable offer status: Green Premium productREACh Regulation
Code EAN: 3389110646641