Schneider Electric SCHNEIDER Télémécanique - Metal safety switch XCSA - 2 NC + 1 NO - slow break - 1 entry tapped Pg 13 - XCSA701
Schneider Electric SCHNEIDER Télémécanique - Metal safety switch XCSA - 2 NC + 1 NO - slow break - 1 entry tapped Pg 13 - XCSA701

Télémécanique - Metal safety switch XCSA - 2 NC + 1 NO - slow break - 1 entry tapped Pg 13 - XCSA701

SKU : XCSA701

Regular price €0,00


/

Contact us for price and lead time for this product. Our team will respond quickly.

Lead time: 2–3 weeks – Ships quickly after order confirmation

Télémécanique - Metal safety switch XCSA - 2 NC + 1 NO - slow break - 1 entry tapped Pg 13 - XCSA701

DESCRIPTION

Range of product: Telemecanique Safety switches XCS
Product or component type: Safety switch
Component name: XCSA
Design: Industrial
Material: Metal
Head type: Key operated turret head
Contacts type and composition: 2 NC + 1 NO
Contact operation: Slow-break, break before make
Cable entry: 1 entry tapped for Pg 13.5
Cable outer diameter: 9...12 mm
Electrical connection: Terminal, clamping capacity: 1 x 0.5...2 x 1.5 mm² with or without cable end
Number of poles: 3
Locking options description: Without locking of actuator
Local signalling: Without
Positive opening: With NC contact
Mechanical durability: 1000000 cycles
Minimum actuation speed: 0.01 m/s
Maximum actuation speed: 0.5 m/s
[Ie] rated operational current: 6 A at 120 V, AC-15, A300 conforming to EN/IEC 60947-5-13 A at 240 V, AC-15, A300 conforming to EN/IEC 60947-5-10.55 A at 125 V, DC-13, Q300 conforming to EN/IEC 60947-5-10.27 A at 250 V, DC-13, Q300 conforming to EN/IEC 60947-5-1
[Ithe] conventional enclosed thermal current: 10 A
[Ui] rated insulation voltage: 300 V conforming to UL 508500 V conforming to EN/IEC 60947-1300 V conforming to CSA C22.2 No 14
[Uimp] rated impulse withstand voltage: 6 kV conforming to EN/IEC 60947-5-1
Short-circuit protection: 10 A cartridge fuse type gG (gl)
Minimum actuator force for extraction: 20 N
Maximum operating rate: 10 cyc/mn for maximum durability
Safety level: Can reach category 4 with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1Can reach PL = e with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1Can reach SIL 3 with the appropriate monitoring system and correctly wired conforming to EN/IEC 61508
Safety reliability data: B10d = 5000000 value given for a life time of 20 years limited by mechanical or contact wear
Body material: Zamak
Head material: Zamak
Depth: 44 mm
Height: 114 mm
Width: 40 mm
Product weight: 0.44 kg
Standards: EN/IEC 60947-5-1CSA C22.2 No 14EN/ISO 12100EN 1088/ISO 14119UL 508EN/IEC 60204-1
Product certifications: CSAUL
Protective treatment: TC
Ambient air temperature for operation: -25...70 °C
Ambient air temperature for storage: -40...70 °C
Vibration resistance: 5 gn (f= 10...500 Hz) conforming to IEC 60068-2-6
Shock resistance: 10 gn for 11 ms conforming to IEC 60068-2-27
Electrical shock protection class: Class I conforming to EN/IEC 61140
IP degree of protection: IP67 conforming to EN/IEC 60529 and EN/IEC 60947-5-1
Sustainable offer status: Green Premium productREACh Regulation
Code EAN: 3389110718867