Schneider Electric SCHNEIDER TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 18 A - 12 V DC coil - LC1D18JL
Schneider Electric SCHNEIDER TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 18 A - 12 V DC coil - LC1D18JL

TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 18 A - 12 V DC coil - LC1D18JL

SKU : LC1D18JL

Regular price €0,00


/

Contact us for price and lead time for this product. Our team will respond quickly.

Lead time: 2–3 weeks – Ships quickly after order confirmation

TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 18 A - 12 V DC coil - LC1D18JL

DESCRIPTION

Range of product: TeSys Deca
Product or component type: Contactor
Device short name: LC1D
Contactor application: Resistive loadMotor control
Utilisation category: AC-1AC-4AC-3AC-3e
Poles description: 3P
[Ue] rated operational voltage: Power circuit: Power circuit:
[Ie] rated operational current: 18 A (at 32 A (at 18 A (at
[Uc] control circuit voltage: 12 V DC
Motor power kW: 4 kW at 220...230 V AC 50/60 Hz (AC-3)7.5 kW at 380...400 V AC 50/60 Hz (AC-3)9 kW at 415...440 V AC 50/60 Hz (AC-3)10 kW at 500 V AC 50/60 Hz (AC-3)10 kW at 660...690 V AC 50/60 Hz (AC-3)4 kW at 400 V AC 50/60 Hz (AC-4)4 kW at 220...230 V AC 50/60 Hz (AC-3e)7.5 kW at 380...400 V AC 50/60 Hz (AC-3e)9 kW at 415...440 V AC 50/60 Hz (AC-3e)10 kW at 500 V AC 50/60 Hz (AC-3e)10 kW at 660...690 V AC 50/60 Hz (AC-3e)
Motor power hp: 1 hp at 115 V AC 50/60 Hz for 1 phase motors3 hp at 230/240 V AC 50/60 Hz for 1 phase motors5 hp at 200/208 V AC 50/60 Hz for 3 phases motors5 hp at 230/240 V AC 50/60 Hz for 3 phases motors10 hp at 460/480 V AC 50/60 Hz for 3 phases motors15 hp at 575/600 V AC 50/60 Hz for 3 phases motors
Compatibility code: LC1D
Pole contact composition: 3 NO
Contact compatibility: M5
Protective cover: With
[Ith] conventional free air thermal current: 10 A (at 60 °C) for signalling circuit32 A (at 60 °C) for power circuit
Irms rated making capacity: 140 A AC for signalling circuit conforming to IEC 60947-5-1250 A DC for signalling circuit conforming to IEC 60947-5-1300 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity: 300 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current: 145 A 40 °C - 10 s for power circuit240 A 40 °C - 1 s for power circuit40 A 40 °C - 10 min for power circuit84 A 40 °C - 1 min for power circuit100 A - 1 s for signalling circuit120 A - 500 ms for signalling circuit140 A - 100 ms for signalling circuit
Associated fuse rating: 10 A gG for signalling circuit conforming to IEC 60947-5-150 A gG at 35 A gG at
Average impedance: 2.5 mOhm - Ith 32 A 50 Hz for power circuit
Power dissipation per pole: 2.5 W AC-10.8 W AC-30.8 W AC-3e
[Ui] rated insulation voltage: Power circuit: 690 V conforming to IEC 60947-4-1Power circuit: 600 V CSA certifiedPower circuit: 600 V UL certifiedSignalling circuit: 690 V conforming to IEC 60947-1Signalling circuit: 600 V CSA certifiedSignalling circuit: 600 V UL certified
Overvoltage category: III
Pollution degree: 3
[Uimp] rated impulse withstand voltage: 6 kV conforming to IEC 60947
Safety reliability level: B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability: 30 Mcycles
Electrical durability: 1.65 Mcycles 18 A AC-3 at Ue 1 Mcycles 32 A AC-1 at Ue 1.65 Mcycles 18 A AC-3e at Ue
Control circuit type: DC low consumption
Coil technology: Built-in bidirectional peak limiting diode suppressor
Control circuit voltage limits: 0.1...0.3 Uc (-40...70 °C):drop-out DC0.8...1.25 Uc (-40...60 °C):operational DC1...1.25 Uc (60...70 °C):operational DC
Inrush power in W: 2.4 W (at 20 °C)
Hold-in power consumption in W: 2.4 W at 20 °C
Operating time: 65.45...88.55 ms closing20...30 ms opening
Time constant: 40 ms
Maximum operating rate: 3600 cyc/h 60 °C
Connections - terminals: Control circuit: screw clamp terminals 1 1...4 mm² - cable stiffness: flexible without cable endControl circuit: screw clamp terminals 2 1...4 mm² - cable stiffness: flexible without cable endControl circuit: screw clamp terminals 1 1...4 mm² - cable stiffness: flexible with cable endControl circuit: screw clamp terminals 2 1...2.5 mm² - cable stiffness: flexible with cable endControl circuit: screw clamp terminals 1 1...4 mm² - cable stiffness: solid without cable endControl circuit: screw clamp terminals 2 1...4 mm² - cable stiffness: solid without cable endPower circuit: screw clamp terminals 1 1.5...6 mm² - cable stiffness: flexible without cable endPower circuit: screw clamp terminals 2 1.5...6 mm² - cable stiffness: flexible without cable endPower circuit: screw clamp terminals 1 1...6 mm² - cable stiffness: flexible with cable endPower circuit: screw clamp terminals 2 1...4 mm² - cable stiffness: flexible with cable endPower circuit: screw clamp terminals 1 1.5...6 mm² - cable stiffness: solid without cable endPower circuit: screw clamp terminals 2 1.5...6 mm² - cable stiffness: solid without cable end
Tightening torque: Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mmPower circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mmControl circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver pozidriv No 2Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver pozidriv No 2
Auxiliary contact composition: 1 NO + 1 NC
Auxiliary contacts type: type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 type mirror contact 1 NC conforming to IEC 60947-4-1
Signalling circuit frequency: 25...400 Hz
Minimum switching voltage: 17 V for signalling circuit
Minimum switching current: 5 mA for signalling circuit
Insulation resistance: > 10 MOhm for signalling circuit
Non-overlap time: 1.5 ms on de-energisation between NC and NO contact1.5 ms on energisation between NC and NO contact
Mounting support: RailPlate
Standards: CSA C22.2 No 14EN 60947-4-1EN 60947-5-1IEC 60947-4-1IEC 60947-5-1UL 508IEC 60335-1
Product certifications: BVCSACCCGOSTGLULDNVRINALROS (Lloyds register of shipping)UKCA
IP degree of protection: IP20 front face conforming to IEC 60529
Protective treatment: TH conforming to IEC 60068-2-30
Climatic withstand: conforming to IACS E10 exposure to damp heat conforming to IEC 60947-1 Annex Q category D exposure to damp heat
Permissible ambient air temperature around the device: -40...60 °C60...70 °C with derating
Operating altitude: 0...3000 m
Fire resistance: 850 °C conforming to IEC 60695-2-1
Flame retardance: V1 conforming to UL 94
Mechanical robustness: Vibrations contactor open (2 Gn, 5...300 Hz) Vibrations contactor closed (4 Gn, 5...300 Hz) Shocks contactor open (10 Gn for 11 ms) Shocks contactor closed (15 Gn for 11 ms)
Height: 77 mm
Width: 45 mm
Depth: 95 mm
Net weight: 0.49 kg
Sustainable offer status: Green Premium productREACh Regulation
Unit Type of Package 1: PCENumber of Units in Package 1
Code EAN: 3389110361735