website Skip to content
English
  • Language EnglishEnglish
  • Language SuomiSuomi
  • Language SvenskaSvenska
EUR
  • GBP
  • USD
  • EUR
Schneider Electric TeSys TeSys D contactor - 4P(2 NO + 2 NC) - AC-1 <= 440 V 125 A 48 V AC 50/60 Hz coil - LC1D80008E7
Schneider Electric TeSys TeSys D contactor - 4P(2 NO + 2 NC) - AC-1 <= 440 V 125 A 48 V AC 50/60 Hz coil - LC1D80008E7

TeSys D contactor - 4P(2 NO + 2 NC) - AC-1 <= 440 V 125 A 48 V AC 50/60 Hz coil - LC1D80008E7

SKU : LC1D80008E7

Regular price €0,00


/

Contact us for price and lead time for this product. Our team will respond quickly.

Lead time: 2–3 weeks – Ships quickly after order confirmation

TeSys D contactor - 4P(2 NO + 2 NC) - AC-1 <= 440 V 125 A 48 V AC 50/60 Hz coil - LC1D80008E7

DESCRIPTION

Range of product: TeSys D
Range: TeSys
Product name: TeSys D
Product or component type: Contactor
Device short name: LC1D
Contactor application: Resistive load
Utilisation category: AC-1
Poles description: 4P
Pole contact composition: 2 NO + 2 NC
[Ue] rated operational voltage: Power circuit: Power circuit:
[Ie] rated operational current: 125 A (at
Control circuit type: AC at 50/60 Hz
[Uc] control circuit voltage: 48 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage: 8 kV conforming to IEC 60947
Overvoltage category: III
[Ith] conventional free air thermal current: 125 A (at 60 °C) for power circuit
Irms rated making capacity: 1100 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity: 1100 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current: 640 A 40 °C - 10 s for power circuit990 A 40 °C - 1 s for power circuit135 A 40 °C - 10 min for power circuit320 A 40 °C - 1 min for power circuit
Associated fuse rating: 200 A gG at 160 A gG at
Average impedance: 0.8 mOhm - Ith 125 A 50 Hz for power circuit
[Ui] rated insulation voltage: Power circuit: 600 V CSA certifiedPower circuit: 600 V UL certifiedPower circuit: 1000 V conforming to IEC 60947-4-1
Electrical durability: 0.8 Mcycles 125 A AC-1 at Ue
Power dissipation per pole: 12.5 W AC-1
Protective cover: Without
Mounting support: PlateRail
Standards: CSA C22.2 No 14EN 60947-4-1EN 60947-5-1IEC 60947-4-1IEC 60947-5-1UL 508
Product certifications: CSABVDNVGOSTULGLLROS (Lloyds register of shipping)RINACCCUKCA
Connections - terminals: Control circuit: screw clamp terminals 2 cable(s) 1...2.5 mm²flexible with cable endControl circuit: screw clamp terminals 1 cable(s) 1...2.5 mm²flexible with cable endControl circuit: screw clamp terminals 1 cable(s) 1...4 mm²flexible without cable endControl circuit: screw clamp terminals 2 cable(s) 1...4 mm²flexible without cable endControl circuit: screw clamp terminals 1 cable(s) 1...4 mm²solid without cable endControl circuit: screw clamp terminals 2 cable(s) 1...4 mm²solid without cable endPower circuit: connector 1 cable(s) 4...50 mm²flexible without cable endPower circuit: connector 2 cable(s) 4...25 mm²flexible without cable endPower circuit: connector 1 cable(s) 4...50 mm²flexible with cable endPower circuit: connector 2 cable(s) 4...16 mm²flexible with cable endPower circuit: connector 1 cable(s) 4...50 mm²solid without cable endPower circuit: connector 2 cable(s) 4...25 mm²solid without cable end
Tightening torque: Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mmControl circuit: 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2Power circuit: 12 N.m - on connector - with screwdriver flat Ø 6 to Ø 8 mmPower circuit: 12 N.m - on connector hexagonal screw head 4 mm
Operating time: 20...35 ms closing6...20 ms opening
Safety reliability level: B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability: 4 Mcycles
Maximum operating rate: 3600 cyc/h 60 °C
Coil technology: Without built-in suppressor module
Control circuit voltage limits: 0.85...1.1 Uc (-40...55 °C):operational AC 60 Hz0.3...0.6 Uc (-40...70 °C):drop-out AC 50/60 Hz0.8...1.1 Uc (-40...55 °C):operational AC 50 Hz1...1.1 Uc (55...70 °C):operational AC 50/60 Hz
Inrush power in VA: 245 VA 60 Hz cos phi 0.75 (at 20 °C)245 VA 50 Hz cos phi 0.75 (at 20 °C)
Hold-in power consumption in VA: 26 VA 60 Hz cos phi 0.3 (at 20 °C)26 VA 50 Hz cos phi 0.3 (at 20 °C)
Heat dissipation: 6...10 W at 50/60 Hz
Contact compatibility: M1
Compatibility code: LC1D
IP degree of protection: IP20 front face conforming to IEC 60529
Protective treatment: TH conforming to IEC 60068-2-30
Pollution degree: 3
Ambient air temperature for operation: -40...60 °C60...70 °C with derating
Ambient air temperature for storage: -60...80 °C
Operating altitude: 0...3000 m
Fire resistance: 850 °C conforming to IEC 60695-2-1
Flame retardance: V1 conforming to UL 94
Mechanical robustness: Vibrations contactor open: 2 Gn, 5...300 HzShocks contactor open: 8 Gn for 11 msVibrations contactor closed: 3 Gn, 5...300 HzShocks contactor closed: 10 Gn for 11 ms
Height: 127 mm
Width: 96 mm
Depth: 140 mm
Product weight: 1.84 kg
Sustainable offer status: Green Premium productREACh Regulation
Code EAN: 3389110075106